Infinite spool (SET_RUNOUT) is set up per print; after a print end or
cancel every lane with a runout lane gets SET_RUNOUT RUNOUT=NONE. Lanes
without one are skipped, so the console stays quiet.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Both now live in the fork https://github.com/MangaValk/bd_pressure
(klipper/, branch main, upstream PR markniu/bd_pressure#13), installed by
its klipper/install.sh and its own Moonraker update_manager entry. The fork's
bdpressure_check.py also reads the v2 firmware diagnostics. bdp_touch.py
stays here. Docs and comments point to the bd_pressure repo.
install.sh only links the files it has, so after this update it no longer
overwrites the bd_pressure links. Run ~/bd_pressure/klipper/install.sh
before updating, or the two links are left dangling.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At the configured 8 the buffer faults after 30 mm in one state; during the
test lines it needs far more to reach its other sensor, so every lane1
calibration on 2026-11-07 paused with AFC NOT FEEDING. With detection off
the buffer switched after ~80 s and the test finished.
_PA_CFG.test_error_sensitivity (2) is set before PA_CALIBRATE and the
[AFC_buffer] config value is restored after it through
_FIRST_LAYER_FAULT_DETECTION ON=0 (lowered=True), which _PRINT_CLEANUP also
calls when the test stops with an error. Nothing changes when detection is
off in the config.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- _PA_CFG.test_z (default 5): LANE_CALIBRATE_PA lowers the nozzle to this
height instead of Z0 before PA_CALIBRATE, so the test lines are extruded
in the air.
- BLOBIFIER: purge_spd_nozzle {"0.4": 150, "0.2": 75} mm/min, picked by
the pa_nozzle save variable (SET_NOZZLE); other sizes use purge_spd.
150 mm/min is about 6 mm3/s, too much for a 0.2 nozzle.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The slicer already retracts on the last move; 5 mm on top was too much.
The soak retract in _LOAD_FOR_CHAMBER keeps the 5 mm default.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
An AFC swap pauses and resumes the file without the PAUSE and RESUME macros
and only stops on AFC's own error state. A failed check called PAUSE, so the
swap went on and restarted the print while the printer counted as paused.
During a swap (file paused, pause_resume not paused) the check now raises an
error at the end of BLOBIFIER_CHECKED, after the temperature and sensor
cleanup. CHANGE_TOOL catches it and pauses through AFC_error. AFC's remap is
skipped, so the message names the SET_MAP command. Other failed checks still
call PAUSE.
Read from AFC 5ea84ea and Klipper 0cee841; render tests only, not yet run on
the printer.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A PA value only holds for the nozzle it was measured with, so values are
saved per nozzle and spool (pa_value_0_4_spool_<id>). SET_NOZZLE sets the
fitted size; a different NOZZLE= from the slicer on PRINT_WARMUP stops the
print before anything heats. The existing values are copied to 0.4 once at
the first start; the old variables stay in the file, unread.
Each nozzle has its own test flow and PA range (0.2: 5 mm3/s, 0-0.196,
starting estimates, about 9 min a lane). The test primes at the test flow
instead of 120 mm3/s.
Remove the Spoolman write: it went to localhost and never arrived, and
nothing read the values back.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
With the chamber open the bed fans only blow room air past the bed. PRINT_WARMUP
sets print_fans_off for CHAMBER 30 or less, _PRINT_CLEANUP clears it. Chamber
prints, the cooldown and heating the bed outside a print are unchanged.
The PID values in PRINT_WARMUP never took effect: the SET_HEATER_TEMPERATURE
override in bed_fans.cfg only passes on the target. The bed keeps its config
values; the misleading console messages are gone.
Tested with rendered macros only, not yet on the printer.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
BED_SCAN_CHECK levels, scans and warns, without heating or touching the bed.
extras/mesh_check.py fits a smooth surface to the mesh and reports areas more
than 0.03 mm from it, and a range over 0.30 mm.
In PRINT_START a failed check pauses before the nozzle heats. Resume sets the
print file back to the PRINT_START line (M26), so it runs again as normal file
G-code. BED_CHECK_IGNORE lets the next failed check only warn.
Tested on saved scans and rendered macros only, not yet on the printer.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A finished soak called RESUME, which goes through AFC_RESUME. HEAT_SOAK pauses
with PAUSE_BASE, so AFC has no saved position and restores 0,0: the toolhead
went to X0 Y0 at Z5 at up to 350 mm/s (AFC.log, 2026-11-04), and _Z_CHECK then
moved straight back. Both nozzle guard stops in z_check (delta -34 and -33)
happened in runs like this, with the toolhead front left. The exact source of
the force is unknown.
Call _RESUME_PRINT directly: it runs RESUME_BASE and skips the purge, because
PAUSE did not park. A manual Resume during a soak still goes through AFC.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Plastic left on the nozzle sets the contact Z too high and squeezes away
during the run. The first real Verify (2026-11-04, about an hour after a PLA
print) saw bd_pressure and Beacon contact sink by about 0.004 mm per point
while proximity held within 0.006 mm, so it asked for a re-run. That cause
is likely but not yet confirmed.
Same order as PRINT_START: QGL, G28 Z, BLOBIFIER_CLEAN with the guard in log
mode, then the contact step. Refuses to start without BLOBIFIER_CLEAN or
_GUARD_ON. Tested against the simulated printer only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
scripts/twist_check.py runs on the Pi and measures or verifies the nozzle vs
Beacon offset; windows explain each step, show progress and give a verdict,
with an HTML report in config/twist_data/. It refuses to start during a print,
stops on unexpected readings and never changes printer.cfg.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At 2.2 force per 0.01 mm (measured 2026-11-02) the old default of 80 was
out of reach within FLOOR from Z0.15 (peak 70 at -0.35); 60 is reached at
about 0.27 mm into the bed and still leaves ~100 readings for the fit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Stepping down 0.005 mm at a time found no touch even 0.25 mm into the bed
(peak 16): the sensor sets a new baseline by itself while the force looks
steady, and the slow ramp looked steady. A quick press gave about 25 per
0.1 mm. BDP_TOUCH now lowers the nozzle in one drip-mode move (SPEED,
default 0.3 mm/s) while a timer reads the force every few ms and stops the
move at STOP; Z per reading comes from stepper_z's past position, the halt
position is recovered like homing.py does. The threshold needs 3 readings
in a row, and the curve is logged also when no touch was found.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
bd_pressure's endstop output is not wired, so BDP_TOUCH lowers the nozzle
in small steps and reads the force after each one, up to a force limit
(default 80) or 0.4 mm below the start, then lifts back. It reports the
threshold height and the zero-force height from a line fit and logs the
curve to klippy.log. TOUCH_COMPARE heats the nozzle to 150C, homes, and
alternates Beacon's contact probe with BDP_TOUCH at one spot, reporting
mean, spread and range of each and of the difference. Refuses while the
bdp_guard is armed or the sensor is in PA mode.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Beacon meshes every 3 min on 2026-11-02 showed the 10 mm plate settles
~33 min after the bed reaches 100C with the chamber at 50C, and ~11 min at
60C with the chamber open. The old soak ended far earlier (bed_core within
5C, or the chamber reaching its target). HEAT_SOAK gets MIN_TIME=<minutes>
(default 0); PRINT_WARMUP soaks on bed_side with RATE 0.05 over 120 s,
SOAK_TEMP 70% of the bed target, MIN_TIME 35 (chamber) / 12 (no chamber),
and skips the soak without a bed target.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The AM312 case light and nozzle LEDs waited for long commands (heat waits,
AFC loads, QGL) because [gcode_button] runs through the G-code queue. The
new module reads the pin itself, keeps the timeout on a reactor timer and
sets the case light with output_pin's send_async_request and the nozzle
LEDs directly on the led_effect object. CASELIGHT and _LIGHTS_ON keep
working; _STATUS_SHOW reads printer.motion_lights.near.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A large, slow first layer tripped AFC's buffer fault detection ("AFC NOT
FEEDING"). _FIRST_LAYER_FAULT_DETECTION ON=1 at the end of PRINT_START
sets first_layer_sensitivity (4: pause after 70 mm instead of 30 mm);
ON=0 restores the [AFC_buffer] config value. The slicer calls ON=0 at
the start of layer 2:
{if layer_num == 1}_FIRST_LAYER_FAULT_DETECTION ON=0{endif}
_PRINT_CLEANUP calls it too, for prints that end in the first layer.
ON=0 only restores what ON=1 changed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
PA_CALIBRATE takes PA_STEP (default 0.002, 0-0.098 over 50 lines).
_PA_CFG.material_pa_step uses 0.004 (0-0.196) for tpu/tpe/flex; soft TPU
measured 0.094, close to the old end. The "no result" rejection uses the
end of the range actually tested.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
_PA_CFG.material_max_volumetric lowers MAX_VOLUMETRIC for materials that
cannot extrude 25 mm3/s (tpu, tpe, flex: 8). The calibration line shows
the flow used.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- LANE_CALIBRATE_PA: when a calibration will run, assign the lane's spool
again (SET_SPOOL_ID) so AFC reads the Spoolman temperature now; AFC
only reads it at spool assignment and Klipper start (TPU calibrated at
210C after Spoolman was set to 230C). The calibration moved to
_LANE_CALIBRATE_PA_RUN, rendered after the refresh.
- bdp_guard: an emergency stop during PA_CALIBRATE leaves the sensor in
PA mode (FIRMWARE_RESTART does not reset it). When arming, read the
mode register and switch the sensor back to probe mode with a fresh
baseline before watching it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- flex_lanes.cfg: a 5 s poller sets SET_LONG_MOVE_SPEED to 50 mm/s (AFC's
minimum) for lanes whose material is TPU/TPE/flex and back to the
configured long_moves_speed otherwise; reapplied after a restart.
- BLOBIFIER_CHECKED: remembers the temperature of the filament in the
nozzle (saved nozzle_last_temp). When it is more than flush_margin
(10C) above the new filament's, the purge runs at that temperature and
the nozzle cools back afterwards, so the leftover melts out (seen: ASA
leftover with TPU loaded at 210C).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- bdpressure_check.py accepted only extension version 1. The sensor now
runs firmware version 2 (bytes 54-65 unchanged, diagnostics added), so
every purge check reported bd_pressure as not answering. Accept 1 and 2.
- _LOAD_FOR_CHAMBER: the Blobifier only purges with the QGL applied, so
the load before the chamber soak skipped its purge (0.0 mm extruded).
Level the gantry and home Z first when the QGL is not applied.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Test print start: guard peaks 1-8 in every phase except the brush scrub
(peak 47, 4 reads above 30 in a row), 0 I2C errors; a light finger push
gives 41. Stop mode for all phases, the brush stays log-only.
The contact homing in HOME restarted 6 times (sample spread too large)
while the nozzle was still heating to 150C; PRINT_WARMUP now waits for a
steady contact temperature first, as PRINT_START does.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
All macros now come from this repo. bd_pressure.cfg ([bdpressure bd_pa]
and the vendor PA_CALIBRATE macros) and Macros/TEST_SPEED.cfg were loose
files in ~/printer_data/config.
PA_CALIBRATE no longer sets Z back to z_current at the end: it was read
before the test ran, so a Z hop in the G28 XY (Beacon home_z_hop) would
leave Klipper believing the nozzle is lower than it is. Z is never switched
off or moved by the test, so it keeps its position without that line.
The ACC_WALL bug (read from ACCEL_TO_DECEL, always 4000) is documented,
not fixed: the cached PA values were measured at 4000.
printer.cfg must drop [include bd_pressure.cfg] and Macros/macros.cfg its
TEST_SPEED include, else the old copies (included later) still win.
Reference values from the load-check-afc branch and from the guard and
Z check tests added to CLAUDE.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- HOME always homes Z with Beacon contact and recalibrates, also when the
printer is already homed (home_method_when_homed = proximity used the
model of an earlier print without touching the bed). PRINT_START homes
Z again after QGL, before the brush takes the nozzle below Z0.
- _Z_CHECK: after the soak, compare Klipper's Z with a BEACON_QUERY
reading at Z3 over the bed centre and stop the print above 1 mm.
Warns and continues when BEACON_QUERY leaves no new
printer.beacon.last_sample.
- Nozzle guard (extras/bdp_guard.py, print/nozzle_guard.cfg): reads the
bd_pressure force over I2C every 20 ms while armed and, in stop mode,
shuts Klipper down on a touch. Armed for HOME X/Y, QGL, Z homing, brush,
mesh and the Z check; starts in log mode to collect peaks per phase.
- Chamber prints: load and purge the first tool before the chamber heats
(_LOAD_FOR_CHAMBER replaces _UNLOAD_FOR_CHAMBER). A cut unload leaves a
piece of PLA in the extruder that softened in the hot chamber and jammed
the ASA load.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
With the chamber heated, a filament left in the toolhead path softens in
the PTFE tube (PLA loaded, ASA print). After the first HOME, PRINT_WARMUP
unloads the loaded lane when it is not mapped to the print's first tool
(PRINT_START would swap it anyway). A failed unload stops the print
before the chamber heats.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
PRINT_WARMUP: bed heats during the warmup, the nozzle only waits while it
is above 170C (Beacon contact limit 180C), one HOME to get over the bed,
then M190 and HEAT_SOAK. No more filament load and 220->150C cycle there.
PRINT_START (on the soaked bed): one QGL, one contact Z calibration, mesh,
heat over the bucket, load the initial tool, PA for all lanes, load the
initial tool again if a calibration changed lanes, G28 X Y reference.
Loading after the contact keeps ooze off the nozzle for the calibration.
PA: calibrate each lane at its own filament temperature (was the
temperature from before CHANGE_TOOL), and apply the loaded lane's PA
after PA_CALIBRATE_ALL_LANES (the last cached lane's PA won before).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The motion timeout switched the nozzle LEDs off during prints, motion
switched them off when idle or paused, the timeout counted from the first
movement, and every _status_* macro stopped the nozzle light.
- _LIGHTS sets case light and nozzle LEDs from presence, print state and
CASELIGHT MODE=AUTO|ON|OFF; the timeout (60 s) starts at the sensor
release
- _STATUS STATE=... replaces the _status_* macros; logo effects only
cover the logo LEDs and use REPLACE=1
- heater gauge while heating, print progress, paused, error flash from
_ERROR, part ready once the bed is cool, dim night mode when idle and
nobody near, cleaning during BLOBIFIER_CLEAN
- removed unused effects and macros, 12 fps for the toolhead effects
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
action_raise_error aborts while the macro renders, so an M117 in the same
macro never ran and errors such as the RESUME lane check only reached the
console. messages.cfg adds _ERROR (M117, then raise in a separate macro)
and _WARN (RESPOND TYPE=error + M117); all errors and warnings use them.
PAUSE shows AFC's error as the pause reason; RESUME, CANCEL_PRINT and
PRINT_WARMUP clear the display.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
PAUSE stores the lane the print needs (AFC's next_lane during a failed
tool change, otherwise the loaded lane). RESUME stops with an error when
another lane or none is loaded; RESUME LANE_CHECK=0 skips the check.
AFC_CLEAR_ALL_MESSAGES clears AFC's whole message queue
(AFC_CLEAR_MESSAGE only removes the first message).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Lanes whose AFC prep and load sensors do not both see filament are
skipped with a message, as are names that are not AFC lanes. The
"complete" message is now a RESPOND, so it appears after the
calibrations instead of before them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A bd_pressure that does not answer used to be reported as "pressure
skipped" and the purge passed unchecked. It now fails the check, so in
enforce mode the printer pauses (and a resume purge stays paused).
PURGE_CHECK_IGNORE_SENSOR lets purges pass without the sensor until the
print ends; _PRINT_CLEANUP clears it so the next print checks again.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
bdpressure.py leaves the extruder at the last PA_CALIBRATE test value
(0.098) when it finds no result, and _PA_AFTER_CALIBRATE saved that as
the calibrated PA (lane1 after an AFC pause, lane5 after the sensor went
silent). A run is now rejected, with nothing cached or written to
Spoolman, when the PA is still at the end of the scan, the printer
paused during the test, or bd_pressure gave too few or too few different
readings. The previous valid PA (or fallback_pa) is applied instead.
bdpressure_check reports pa_points and pa_distinct from the bdpressure
module's last PA_CALIBRATE data for this.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
bdwidth's motion reading stays at 0, its per-reading width compensation
made the flow jump between 77 and 119%, and a USB dropout shut down
Klipper. PRINT_START no longer enables it. _PRINT_CLEANUP,
BLOBIFIER_CHECKED and PURGE_UNTIL_EMPTY only send bdwidth commands when
[bdwidth fila_width_0] exists, and bdwidth_status reports present: False
with neutral values when it is not configured, so the section can be
removed from printer.cfg.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
_RESUME_PRINT purges 40 mm with BLOBIFIER_CHECKED (instead of the 2 mm
unretract), so the nozzle is primed, wiped and checked before going back
to the print. A failed purge check raises an error that aborts the whole
resume, AFC_RESUME's restore included, so the printer stays paused; the
next RESUME checks again. RESUME PURGE=0 skips the purge.
The purge check records a failure in _PURGE_CHECK_CFG.last_failed, since
its PAUSE has no effect while the printer is already paused.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The CCD motion reading stays at 0 (actual_total_move:0), so motion mode
only produced false "Rounout" messages. ENABLE_WIDTH keeps the flow
compensation and the runout on a missing width; clogs and breaks are
left to AFC's buffer fault detection (filament_error_sensitivity).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Klipper's G10 retracts only once until a G11, and nothing sends G11 on
this printer: the G10 in PRINT_WARMUP used up the retract, so PRINT_END
never retracted and the nozzle leaked while cooling down.
- _NOZZLE_RETRACT retracts and remembers the amount in the saved
variable nozzle_retract (survives restarts, capped at 15 mm).
PRINT_END retracts 5 mm, PRINT_WARMUP 2 mm, CANCEL_PRINT 5 mm plus the
park/PAUSE retract.
- _NOZZLE_UNRETRACT in PRINT_START pushes it back over the bucket before
the wipe.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- bd_pa_spoolman.cfg renames AFC's SET_SPOOL_ID, so klipper-macros.cfg
must be included after [include AFC/*.cfg]; the README said otherwise.
- install.sh links scripts/ as ~/printer_data/config/klipper-macros-scripts
so the scripts can be edited in Mainsail/Fluidd.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- RESUME is defined only in print/pause_resume.cfg; heat_soak.cfg's
duplicate replaced it (no unretract, no fan restore). It now runs
HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE.
- PAUSE runs PAUSE_BASE first, then retracts and parks once (X20 Y345);
a parked flag makes resume undo only what PAUSE did.
- New _PRINT_CLEANUP shared by PRINT_END and CANCEL_PRINT: heaters incl.
iHEATER_OFF, fan, M221 S100, bdwidth off, mesh and skew cleared.
In PRINT_END it runs after RESTORE_GCODE_STATE so the flow reset sticks.
- Add CLAUDE.md and tools/effective_config.py.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Split the macro files into folders by topic (print, heating, afc,
pressure_advance, spoolman, leds, sensors); klipper-macros.cfg is the
one file printer.cfg includes. Macros moved unchanged; the effective
config is identical apart from the paths of the PA shell scripts.
- Add the modified Blobifier (Turtleblobifier for AFC) and define
[save_variables] once in save_variables.cfg instead of in both
blobifier.cfg and the PA macros (same file, bd_pa_variables.cfg).
- PRINT_WARMUP: heat to the loaded lane's temperature before the first
tool change. AFC skips heating when the loaded lane's tool number is
not in the print file's temperature list, and the unload then failed
below min_extrude_temp.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Macros as they run on the printer (Voron 2.4 + AFC Box Turtle +
Blobifier + Beacon + bd_pressure + bdwidth + iHeater), the Klipper
modules they need (xy_drift, bdwidth_status, bdpressure_check), MCU
firmware update scripts, install.sh with Moonraker update manager
support, and READMEs.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>