TWIST_CALIBRATE: wipe the nozzle before the contact step
Plastic left on the nozzle sets the contact Z too high and squeezes away during the run. The first real Verify (2026-11-04, about an hour after a PLA print) saw bd_pressure and Beacon contact sink by about 0.004 mm per point while proximity held within 0.006 mm, so it asked for a re-run. That cause is likely but not yet confirmed. Same order as PRINT_START: QGL, G28 Z, BLOBIFIER_CLEAN with the guard in log mode, then the contact step. Refuses to start without BLOBIFIER_CLEAN or _GUARD_ON. Tested against the simulated printer only. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
7bee9a1ecd
commit
1fc4b26366
3 files changed
+14
-5
No files matched your search
@@ -80,7 +80,7 @@ gcode:
|
||||
{% if bed > 40 %}
|
||||
RESPOND TYPE=command MSG="action:prompt_text Note: the bed is at {bed|int} C. The reference runs were on a cold bed, so wait for it to cool unless you want this on purpose."
|
||||
{% endif %}
|
||||
RESPOND TYPE=command MSG="action:prompt_text It heats the nozzle to 150 C, homes, levels and takes {'25' if mode == 'measure' else '17'} minutes. The configuration is not changed."
|
||||
RESPOND TYPE=command MSG="action:prompt_text It heats the nozzle to 150 C, homes, levels, wipes the nozzle on the brush and takes {'25' if mode == 'measure' else '17'} minutes. The configuration is not changed."
|
||||
RESPOND TYPE=command MSG="action:prompt_footer_button Back|TWIST_CALIBRATE|secondary"
|
||||
RESPOND TYPE=command MSG="action:prompt_footer_button All checked, start|_TWIST_START MODE={mode}|primary"
|
||||
RESPOND TYPE=command MSG="action:prompt_show"
|
||||
|
||||
Reference in new issue
Block a user