Commit Graph
8 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 93f00c87a7 Stop using bdwidth while printing, work without it
bdwidth's motion reading stays at 0, its per-reading width compensation
made the flow jump between 77 and 119%, and a USB dropout shut down
Klipper. PRINT_START no longer enables it. _PRINT_CLEANUP,
BLOBIFIER_CHECKED and PURGE_UNTIL_EMPTY only send bdwidth commands when
[bdwidth fila_width_0] exists, and bdwidth_status reports present: False
with neutral values when it is not configured, so the section can be
removed from printer.cfg.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 18:18:40 +02:00
mangavalkandClaude Opus 5.5 eb7e0d4482 Purge and check before resuming after a PAUSE
_RESUME_PRINT purges 40 mm with BLOBIFIER_CHECKED (instead of the 2 mm
unretract), so the nozzle is primed, wiped and checked before going back
to the print. A failed purge check raises an error that aborts the whole
resume, AFC_RESUME's restore included, so the printer stays paused; the
next RESUME checks again. RESUME PURGE=0 skips the purge.

The purge check records a failure in _PURGE_CHECK_CFG.last_failed, since
its PAUSE has no effect while the printer is already paused.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 14:08:53 +02:00
mangavalkandClaude Opus 5.5 b6379621f6 bdwidth: width only in PRINT_START
The CCD motion reading stays at 0 (actual_total_move:0), so motion mode
only produced false "Rounout" messages. ENABLE_WIDTH keeps the flow
compensation and the runout on a missing width; clogs and breaks are
left to AFC's buffer fault detection (filament_error_sensitivity).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 20:31:43 +02:00
mangavalkandClaude Opus 5.5 e152246e9f Retract at print end, undo it at print start
Klipper's G10 retracts only once until a G11, and nothing sends G11 on
this printer: the G10 in PRINT_WARMUP used up the retract, so PRINT_END
never retracted and the nozzle leaked while cooling down.

- _NOZZLE_RETRACT retracts and remembers the amount in the saved
  variable nozzle_retract (survives restarts, capped at 15 mm).
  PRINT_END retracts 5 mm, PRINT_WARMUP 2 mm, CANCEL_PRINT 5 mm plus the
  park/PAUSE retract.
- _NOZZLE_UNRETRACT in PRINT_START pushes it back over the bucket before
  the wipe.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 15:01:55 +02:00
mangavalkandClaude Opus 5.5 179bd0991b Include after AFC, link scripts/ into the config folder
- bd_pa_spoolman.cfg renames AFC's SET_SPOOL_ID, so klipper-macros.cfg
  must be included after [include AFC/*.cfg]; the README said otherwise.
- install.sh links scripts/ as ~/printer_data/config/klipper-macros-scripts
  so the scripts can be edited in Mainsail/Fluidd.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:28:52 +02:00
mangavalkandClaude Opus 5.5 9dc733b5bb Fix pause/resume chain, shared print cleanup, add CLAUDE.md
- RESUME is defined only in print/pause_resume.cfg; heat_soak.cfg's
  duplicate replaced it (no unretract, no fan restore). It now runs
  HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE.
- PAUSE runs PAUSE_BASE first, then retracts and parks once (X20 Y345);
  a parked flag makes resume undo only what PAUSE did.
- New _PRINT_CLEANUP shared by PRINT_END and CANCEL_PRINT: heaters incl.
  iHEATER_OFF, fan, M221 S100, bdwidth off, mesh and skew cleared.
  In PRINT_END it runs after RESTORE_GCODE_STATE so the flow reset sticks.
- Add CLAUDE.md and tools/effective_config.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:20:28 +02:00
mangavalkandClaude Opus 5.5 eaf9c82617 Group macros by topic, add Blobifier, fix first tool change
- Split the macro files into folders by topic (print, heating, afc,
  pressure_advance, spoolman, leds, sensors); klipper-macros.cfg is the
  one file printer.cfg includes. Macros moved unchanged; the effective
  config is identical apart from the paths of the PA shell scripts.
- Add the modified Blobifier (Turtleblobifier for AFC) and define
  [save_variables] once in save_variables.cfg instead of in both
  blobifier.cfg and the PA macros (same file, bd_pa_variables.cfg).
- PRINT_WARMUP: heat to the loaded lane's temperature before the first
  tool change. AFC skips heating when the loaded lane's tool number is
  not in the print file's temperature list, and the unload then failed
  below min_extrude_temp.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 14:24:37 +02:00
mangavalkandClaude Opus 5.5 6dbb4ca3fb Initial import of my Klipper macros, modules and scripts
Macros as they run on the printer (Voron 2.4 + AFC Box Turtle +
Blobifier + Beacon + bd_pressure + bdwidth + iHeater), the Klipper
modules they need (xy_drift, bdwidth_status, bdpressure_check), MCU
firmware update scripts, install.sh with Moonraker update manager
support, and READMEs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 13:45:11 +02:00