Commit Graph
16 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 dae8afac20 Move bdpressure_check.py and bdp_guard.py to the bd_pressure repo
Both now live in the fork https://github.com/MangaValk/bd_pressure
(klipper/, branch main, upstream PR markniu/bd_pressure#13), installed by
its klipper/install.sh and its own Moonraker update_manager entry. The fork's
bdpressure_check.py also reads the v2 firmware diagnostics. bdp_touch.py
stays here. Docs and comments point to the bd_pressure repo.

install.sh only links the files it has, so after this update it no longer
overwrites the bd_pressure links. Run ~/bd_pressure/klipper/install.sh
before updating, or the two links are left dangling.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-07 16:52:36 +01:00
mangavalkandClaude Opus 5.5 19c70ebeb8 Purge check: stop an infinite spool swap when the check fails
An AFC swap pauses and resumes the file without the PAUSE and RESUME macros
and only stops on AFC's own error state. A failed check called PAUSE, so the
swap went on and restarted the print while the printer counted as paused.

During a swap (file paused, pause_resume not paused) the check now raises an
error at the end of BLOBIFIER_CHECKED, after the temperature and sensor
cleanup. CHANGE_TOOL catches it and pauses through AFC_error. AFC's remap is
skipped, so the message names the SET_MAP command. Other failed checks still
call PAUSE.

Read from AFC 5ea84ea and Klipper 0cee841; render tests only, not yet run on
the printer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 20:58:17 +01:00
mangavalkandClaude Opus 5.5 b415cbebf4 PA values per nozzle: SET_NOZZLE, slicer check, no Spoolman write
A PA value only holds for the nozzle it was measured with, so values are
saved per nozzle and spool (pa_value_0_4_spool_<id>). SET_NOZZLE sets the
fitted size; a different NOZZLE= from the slicer on PRINT_WARMUP stops the
print before anything heats. The existing values are copied to 0.4 once at
the first start; the old variables stay in the file, unread.

Each nozzle has its own test flow and PA range (0.2: 5 mm3/s, 0-0.196,
starting estimates, about 9 min a lane). The test primes at the test flow
instead of 120 mm3/s.

Remove the Spoolman write: it went to localhost and never arrived, and
nothing read the values back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 19:49:25 +01:00
mangavalkandClaude Opus 5.5 99b7109b5b Add a bed check: warn about bumps and flatness, pause PRINT_START on a failure
BED_SCAN_CHECK levels, scans and warns, without heating or touching the bed.
extras/mesh_check.py fits a smooth surface to the mesh and reports areas more
than 0.03 mm from it, and a range over 0.30 mm.

In PRINT_START a failed check pauses before the nozzle heats. Resume sets the
print file back to the PRINT_START line (M26), so it runs again as normal file
G-code. BED_CHECK_IGNORE lets the next failed check only warn.

Tested on saved scans and rendered macros only, not yet on the printer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 16:16:36 +01:00
mangavalkandClaude Opus 5.5 92d86d6bfd TWIST_CALIBRATE: axis twist calibration from Mainsail
scripts/twist_check.py runs on the Pi and measures or verifies the nozzle vs
Beacon offset; windows explain each step, show progress and give a verdict,
with an HTML report in config/twist_data/. It refuses to start during a print,
stops on unexpected readings and never changes printer.cfg.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-03 22:53:48 +01:00
mangavalkandClaude Opus 5.5 464a7c1046 CLAUDE.md: purge check peaks up to 246 with ASA at 250-260C
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 15:20:02 +02:00
mangavalkandClaude Opus 5.5 b9d2f3a062 Nozzle guard in stop mode (brush log-only), wait for the nozzle before HOME
Test print start: guard peaks 1-8 in every phase except the brush scrub
(peak 47, 4 reads above 30 in a row), 0 I2C errors; a light finger push
gives 41. Stop mode for all phases, the brush stays log-only.

The contact homing in HOME restarted 6 times (sample spread too large)
while the nozzle was still heating to 150C; PRINT_WARMUP now waits for a
steady contact temperature first, as PRINT_START does.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 23:25:28 +02:00
mangavalkandClaude Opus 5.5 a16b57a0a9 Move bd_pressure.cfg and TEST_SPEED into the repo
All macros now come from this repo. bd_pressure.cfg ([bdpressure bd_pa]
and the vendor PA_CALIBRATE macros) and Macros/TEST_SPEED.cfg were loose
files in ~/printer_data/config.

PA_CALIBRATE no longer sets Z back to z_current at the end: it was read
before the test ran, so a Z hop in the G28 XY (Beacon home_z_hop) would
leave Klipper believing the nozzle is lower than it is. Z is never switched
off or moved by the test, so it keeps its position without that line.
The ACC_WALL bug (read from ACCEL_TO_DECEL, always 4000) is documented,
not fixed: the cached PA values were measured at 4000.

printer.cfg must drop [include bd_pressure.cfg] and Macros/macros.cfg its
TEST_SPEED include, else the old copies (included later) still win.

Reference values from the load-check-afc branch and from the guard and
Z check tests added to CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 23:11:02 +02:00
mangavalkandClaude Opus 5.5 61fa8acb05 Print start: contact homing, nozzle guard, Z check, purge before chamber heat
- HOME always homes Z with Beacon contact and recalibrates, also when the
  printer is already homed (home_method_when_homed = proximity used the
  model of an earlier print without touching the bed). PRINT_START homes
  Z again after QGL, before the brush takes the nozzle below Z0.
- _Z_CHECK: after the soak, compare Klipper's Z with a BEACON_QUERY
  reading at Z3 over the bed centre and stop the print above 1 mm.
  Warns and continues when BEACON_QUERY leaves no new
  printer.beacon.last_sample.
- Nozzle guard (extras/bdp_guard.py, print/nozzle_guard.cfg): reads the
  bd_pressure force over I2C every 20 ms while armed and, in stop mode,
  shuts Klipper down on a touch. Armed for HOME X/Y, QGL, Z homing, brush,
  mesh and the Z check; starts in log mode to collect peaks per phase.
- Chamber prints: load and purge the first tool before the chamber heats
  (_LOAD_FOR_CHAMBER replaces _UNLOAD_FOR_CHAMBER). A cut unload leaves a
  piece of PLA in the extruder that softened in the hot chamber and jammed
  the ASA load.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 22:39:26 +02:00
mangavalkandClaude Opus 5.5 fbdb2d5e1d Show errors and warnings on the display (_ERROR, _WARN)
action_raise_error aborts while the macro renders, so an M117 in the same
macro never ran and errors such as the RESUME lane check only reached the
console. messages.cfg adds _ERROR (M117, then raise in a separate macro)
and _WARN (RESPOND TYPE=error + M117); all errors and warnings use them.
PAUSE shows AFC's error as the pause reason; RESUME, CANCEL_PRINT and
PRINT_WARMUP clear the display.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-16 17:41:41 +02:00
mangavalkandClaude Opus 5.5 93f00c87a7 Stop using bdwidth while printing, work without it
bdwidth's motion reading stays at 0, its per-reading width compensation
made the flow jump between 77 and 119%, and a USB dropout shut down
Klipper. PRINT_START no longer enables it. _PRINT_CLEANUP,
BLOBIFIER_CHECKED and PURGE_UNTIL_EMPTY only send bdwidth commands when
[bdwidth fila_width_0] exists, and bdwidth_status reports present: False
with neutral values when it is not configured, so the section can be
removed from printer.cfg.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 18:18:40 +02:00
mangavalkandClaude Opus 5.5 eb7e0d4482 Purge and check before resuming after a PAUSE
_RESUME_PRINT purges 40 mm with BLOBIFIER_CHECKED (instead of the 2 mm
unretract), so the nozzle is primed, wiped and checked before going back
to the print. A failed purge check raises an error that aborts the whole
resume, AFC_RESUME's restore included, so the printer stays paused; the
next RESUME checks again. RESUME PURGE=0 skips the purge.

The purge check records a failure in _PURGE_CHECK_CFG.last_failed, since
its PAUSE has no effect while the printer is already paused.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 14:08:53 +02:00
mangavalkandClaude Opus 5.5 b6379621f6 bdwidth: width only in PRINT_START
The CCD motion reading stays at 0 (actual_total_move:0), so motion mode
only produced false "Rounout" messages. ENABLE_WIDTH keeps the flow
compensation and the runout on a missing width; clogs and breaks are
left to AFC's buffer fault detection (filament_error_sensitivity).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 20:31:43 +02:00
mangavalkandClaude Opus 5.5 e152246e9f Retract at print end, undo it at print start
Klipper's G10 retracts only once until a G11, and nothing sends G11 on
this printer: the G10 in PRINT_WARMUP used up the retract, so PRINT_END
never retracted and the nozzle leaked while cooling down.

- _NOZZLE_RETRACT retracts and remembers the amount in the saved
  variable nozzle_retract (survives restarts, capped at 15 mm).
  PRINT_END retracts 5 mm, PRINT_WARMUP 2 mm, CANCEL_PRINT 5 mm plus the
  park/PAUSE retract.
- _NOZZLE_UNRETRACT in PRINT_START pushes it back over the bucket before
  the wipe.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 15:01:55 +02:00
mangavalkandClaude Opus 5.5 179bd0991b Include after AFC, link scripts/ into the config folder
- bd_pa_spoolman.cfg renames AFC's SET_SPOOL_ID, so klipper-macros.cfg
  must be included after [include AFC/*.cfg]; the README said otherwise.
- install.sh links scripts/ as ~/printer_data/config/klipper-macros-scripts
  so the scripts can be edited in Mainsail/Fluidd.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:28:52 +02:00
mangavalkandClaude Opus 5.5 9dc733b5bb Fix pause/resume chain, shared print cleanup, add CLAUDE.md
- RESUME is defined only in print/pause_resume.cfg; heat_soak.cfg's
  duplicate replaced it (no unretract, no fan restore). It now runs
  HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE.
- PAUSE runs PAUSE_BASE first, then retracts and parks once (X20 Y345);
  a parked flag makes resume undo only what PAUSE did.
- New _PRINT_CLEANUP shared by PRINT_END and CANCEL_PRINT: heaters incl.
  iHEATER_OFF, fan, M221 S100, bdwidth off, mesh and skew cleared.
  In PRINT_END it runs after RESTORE_GCODE_STATE so the flow reset sticks.
- Add CLAUDE.md and tools/effective_config.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:20:28 +02:00