Files
klipper-macros/macros/afc/auto_resume.cfg
T
mangavalkandClaude Opus 5.5 2629e70fad Auto-resume only on NOT FEEDING; purge check fails on pressure left after the purge
A CLOG DETECTED pause is usually a real blockage: on 2026-11-17 a nozzle
blocked right after a swap, the purge check passed (a blocked nozzle also
builds pressure) and the automatic resume only printed air until the next
CLOG pause. CLOG messages are still cleared after a resume, so a leftover
one cannot hide the next NOT FEEDING message.

The purge check now also fails when bd_pressure's delta is still above
pressure_max_delta (15) when the check stops: 16 good purges -3..+10, two
long purges into the blocked nozzle +19/+21 (the short ones did not show it).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 11:16:50 +01:00

107 lines
6.1 KiB
INI

# Automatic resume after an AFC "NOT FEEDING" buffer fault
#
# When AFC pauses a print because the buffer stayed empty too long,
# PAUSE (print/pause_resume.cfg) calls _AUTO_RESUME_ARM. After `delay` seconds
# _AUTO_RESUME runs the normal RESUME: AFC clears its error, the lane check
# runs, and _RESUME_PRINT purges into the Blobifier with the purge check. A
# failed check (or lane check) stops that RESUME as usual, so the print stays
# paused and waits for you.
#
# Limits, so a real problem (tangled spool, grinding extruder, clog) is not
# hidden: at most `max_per_print` automatic resumes per print, and none when
# the previous one was less than `min_interval` minutes of printing ago. After
# that the print stays paused like before.
#
# Only between _PRINT_START_FINISH and the end of the print (`active`): a pause
# during PRINT_START or a PA test needs CLEAR_PAUSE, not RESUME.
#
# Turn off: SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=enabled VALUE=False
# (until the next restart; change `enabled` below to keep it off)
[gcode_macro _AUTO_RESUME_CFG]
description: Settings and state for the automatic resume after an AFC buffer fault
variable_enabled: True
variable_max_per_print: 2 # automatic resumes per print
variable_min_interval: 10 # minutes of printing since the previous automatic resume
variable_delay: 5 # seconds after the pause (AFC finishes its own pause first)
variable_faults: ['NOT FEEDING'] # text in AFC's error message
# Not 'CLOG DETECTED' (buffer stayed full: the extruder takes no filament):
# that is usually a real blockage. On 2026-11-17 a nozzle blocked right after a
# swap; the purge check still passed (a blocked nozzle also builds pressure),
# so the automatic resume only printed air until the next CLOG pause.
variable_clear_faults: ['NOT FEEDING', 'CLOG DETECTED'] # removed from AFC's queue after any resume
# State (set by the macros)
variable_active: False # True from _PRINT_START_FINISH to the end of the print
variable_count: 0 # automatic resumes in this print
variable_last_at: -1.0 # print_duration (s) of the last automatic resume, -1 = none
variable_pending: '' # fault the timer is waiting to resume from
gcode:
RESPOND MSG="Auto-resume: {'on' if enabled else 'off'}, {'active' if active else 'not active'}, {count}/{max_per_print} used in this print"
# Called by _PRINT_START_FINISH (ON=1) and _PRINT_CLEANUP (ON=0)
[gcode_macro _AUTO_RESUME_ACTIVE]
description: Start (ON=1) or end (ON=0) the automatic resume for a print
gcode:
{% set on = params.ON|default(1)|int %}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=active VALUE={True if on else False}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=count VALUE=0
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=last_at VALUE=-1.0
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="''"
UPDATE_DELAYED_GCODE ID=_AUTO_RESUME DURATION=0
{% if on and 'AFC' in printer %}
# Old messages would be read as this print's fault: start empty
AFC_CLEAR_ALL_MESSAGES
{% endif %}
# Called by PAUSE when it pauses a print. AFC's message queue shows its oldest
# message first; _RESUME_PRINT removes a buffer fault message once resumed, so
# the oldest one is this pause's.
[gcode_macro _AUTO_RESUME_ARM]
description: Start the automatic resume timer when AFC paused for a buffer fault and the limits allow it
gcode:
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
{% set has_afc = 'AFC' in printer %}
{% set msg = printer.AFC.message.message|default('') if has_afc else '' %}
{% set fault = (cfg.faults|select('in', msg)|list + [''])[0] %}
{% set now = printer.print_stats.print_duration|float %}
{% if cfg.enabled and cfg.active and has_afc and printer.AFC.error_state and fault %}
{% if cfg.count >= cfg.max_per_print %}
_WARN MSG="Auto-resume: not resuming after AFC {fault}, already {cfg.count} automatic resumes in this print. Check the lane, then RESUME." DISPLAY="AFC {fault}: check, then RESUME"
{% elif cfg.last_at >= 0 and now - cfg.last_at < cfg.min_interval * 60 %}
_WARN MSG="Auto-resume: not resuming after AFC {fault}, the last automatic resume was only {((now - cfg.last_at) / 60)|round(1)} min of printing ago. Check the lane, then RESUME." DISPLAY="AFC {fault} again: check, then RESUME"
{% else %}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="'{fault}'"
RESPOND MSG="Auto-resume: AFC {fault}, resuming in {cfg.delay} s with the purge check ({cfg.count + 1}/{cfg.max_per_print})"
UPDATE_DELAYED_GCODE ID=_AUTO_RESUME DURATION={cfg.delay}
{% endif %}
{% endif %}
[delayed_gcode _AUTO_RESUME]
gcode:
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
{% set fault = cfg.pending %}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="''"
# Only when nothing changed since the pause: still paused, still AFC's
# error (a manual RESUME or CANCEL in the meantime ends it)
{% if fault and cfg.active and printer.print_stats.state == 'paused'
and printer.pause_resume.is_paused and printer.AFC.error_state %}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=count VALUE={cfg.count + 1}
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=last_at VALUE={printer.print_stats.print_duration|float}
RESPOND MSG="Auto-resume {cfg.count + 1}/{cfg.max_per_print} after AFC {fault}"
M117 Auto-resume {cfg.count + 1}/{cfg.max_per_print}: AFC {fault}
RESUME
{% endif %}
# Called by _RESUME_PRINT after a resume: remove a buffer fault message from
# the front of AFC's queue, so the next pause reads its own message. Also a
# CLOG message after a manual RESUME: left at the front, it would hide the next
# NOT FEEDING message and block that automatic resume.
[gcode_macro _AUTO_RESUME_CLEAR_FAULT]
description: Helper: drop AFC's buffer fault message after a resume
gcode:
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
{% set msg = printer.AFC.message.message|default('') if 'AFC' in printer else '' %}
{% if msg and cfg.clear_faults|select('in', msg)|list %}
AFC_CLEAR_MESSAGE
{% endif %}