Commit Graph
14 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 b415cbebf4 PA values per nozzle: SET_NOZZLE, slicer check, no Spoolman write
A PA value only holds for the nozzle it was measured with, so values are
saved per nozzle and spool (pa_value_0_4_spool_<id>). SET_NOZZLE sets the
fitted size; a different NOZZLE= from the slicer on PRINT_WARMUP stops the
print before anything heats. The existing values are copied to 0.4 once at
the first start; the old variables stay in the file, unread.

Each nozzle has its own test flow and PA range (0.2: 5 mm3/s, 0-0.196,
starting estimates, about 9 min a lane). The test primes at the test flow
instead of 120 mm3/s.

Remove the Spoolman write: it went to localhost and never arrived, and
nothing read the values back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 19:49:25 +01:00
mangavalkandClaude Opus 5.5 99b7109b5b Add a bed check: warn about bumps and flatness, pause PRINT_START on a failure
BED_SCAN_CHECK levels, scans and warns, without heating or touching the bed.
extras/mesh_check.py fits a smooth surface to the mesh and reports areas more
than 0.03 mm from it, and a range over 0.30 mm.

In PRINT_START a failed check pauses before the nozzle heats. Resume sets the
print file back to the PRINT_START line (M26), so it runs again as normal file
G-code. BED_CHECK_IGNORE lets the next failed check only warn.

Tested on saved scans and rendered macros only, not yet on the printer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 16:16:36 +01:00
mangavalkandClaude Opus 5.5 92d86d6bfd TWIST_CALIBRATE: axis twist calibration from Mainsail
scripts/twist_check.py runs on the Pi and measures or verifies the nozzle vs
Beacon offset; windows explain each step, show progress and give a verdict,
with an HTML report in config/twist_data/. It refuses to start during a print,
stops on unexpected readings and never changes printer.cfg.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-03 22:53:48 +01:00
mangavalkandClaude Opus 5.5 464a7c1046 CLAUDE.md: purge check peaks up to 246 with ASA at 250-260C
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 15:20:02 +02:00
mangavalkandClaude Opus 5.5 b9d2f3a062 Nozzle guard in stop mode (brush log-only), wait for the nozzle before HOME
Test print start: guard peaks 1-8 in every phase except the brush scrub
(peak 47, 4 reads above 30 in a row), 0 I2C errors; a light finger push
gives 41. Stop mode for all phases, the brush stays log-only.

The contact homing in HOME restarted 6 times (sample spread too large)
while the nozzle was still heating to 150C; PRINT_WARMUP now waits for a
steady contact temperature first, as PRINT_START does.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 23:25:28 +02:00
mangavalkandClaude Opus 5.5 a16b57a0a9 Move bd_pressure.cfg and TEST_SPEED into the repo
All macros now come from this repo. bd_pressure.cfg ([bdpressure bd_pa]
and the vendor PA_CALIBRATE macros) and Macros/TEST_SPEED.cfg were loose
files in ~/printer_data/config.

PA_CALIBRATE no longer sets Z back to z_current at the end: it was read
before the test ran, so a Z hop in the G28 XY (Beacon home_z_hop) would
leave Klipper believing the nozzle is lower than it is. Z is never switched
off or moved by the test, so it keeps its position without that line.
The ACC_WALL bug (read from ACCEL_TO_DECEL, always 4000) is documented,
not fixed: the cached PA values were measured at 4000.

printer.cfg must drop [include bd_pressure.cfg] and Macros/macros.cfg its
TEST_SPEED include, else the old copies (included later) still win.

Reference values from the load-check-afc branch and from the guard and
Z check tests added to CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 23:11:02 +02:00
mangavalkandClaude Opus 5.5 61fa8acb05 Print start: contact homing, nozzle guard, Z check, purge before chamber heat
- HOME always homes Z with Beacon contact and recalibrates, also when the
  printer is already homed (home_method_when_homed = proximity used the
  model of an earlier print without touching the bed). PRINT_START homes
  Z again after QGL, before the brush takes the nozzle below Z0.
- _Z_CHECK: after the soak, compare Klipper's Z with a BEACON_QUERY
  reading at Z3 over the bed centre and stop the print above 1 mm.
  Warns and continues when BEACON_QUERY leaves no new
  printer.beacon.last_sample.
- Nozzle guard (extras/bdp_guard.py, print/nozzle_guard.cfg): reads the
  bd_pressure force over I2C every 20 ms while armed and, in stop mode,
  shuts Klipper down on a touch. Armed for HOME X/Y, QGL, Z homing, brush,
  mesh and the Z check; starts in log mode to collect peaks per phase.
- Chamber prints: load and purge the first tool before the chamber heats
  (_LOAD_FOR_CHAMBER replaces _UNLOAD_FOR_CHAMBER). A cut unload leaves a
  piece of PLA in the extruder that softened in the hot chamber and jammed
  the ASA load.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 22:39:26 +02:00
mangavalkandClaude Opus 5.5 fbdb2d5e1d Show errors and warnings on the display (_ERROR, _WARN)
action_raise_error aborts while the macro renders, so an M117 in the same
macro never ran and errors such as the RESUME lane check only reached the
console. messages.cfg adds _ERROR (M117, then raise in a separate macro)
and _WARN (RESPOND TYPE=error + M117); all errors and warnings use them.
PAUSE shows AFC's error as the pause reason; RESUME, CANCEL_PRINT and
PRINT_WARMUP clear the display.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-16 17:41:41 +02:00
mangavalkandClaude Opus 5.5 93f00c87a7 Stop using bdwidth while printing, work without it
bdwidth's motion reading stays at 0, its per-reading width compensation
made the flow jump between 77 and 119%, and a USB dropout shut down
Klipper. PRINT_START no longer enables it. _PRINT_CLEANUP,
BLOBIFIER_CHECKED and PURGE_UNTIL_EMPTY only send bdwidth commands when
[bdwidth fila_width_0] exists, and bdwidth_status reports present: False
with neutral values when it is not configured, so the section can be
removed from printer.cfg.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 18:18:40 +02:00
mangavalkandClaude Opus 5.5 eb7e0d4482 Purge and check before resuming after a PAUSE
_RESUME_PRINT purges 40 mm with BLOBIFIER_CHECKED (instead of the 2 mm
unretract), so the nozzle is primed, wiped and checked before going back
to the print. A failed purge check raises an error that aborts the whole
resume, AFC_RESUME's restore included, so the printer stays paused; the
next RESUME checks again. RESUME PURGE=0 skips the purge.

The purge check records a failure in _PURGE_CHECK_CFG.last_failed, since
its PAUSE has no effect while the printer is already paused.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 14:08:53 +02:00
mangavalkandClaude Opus 5.5 b6379621f6 bdwidth: width only in PRINT_START
The CCD motion reading stays at 0 (actual_total_move:0), so motion mode
only produced false "Rounout" messages. ENABLE_WIDTH keeps the flow
compensation and the runout on a missing width; clogs and breaks are
left to AFC's buffer fault detection (filament_error_sensitivity).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 20:31:43 +02:00
mangavalkandClaude Opus 5.5 e152246e9f Retract at print end, undo it at print start
Klipper's G10 retracts only once until a G11, and nothing sends G11 on
this printer: the G10 in PRINT_WARMUP used up the retract, so PRINT_END
never retracted and the nozzle leaked while cooling down.

- _NOZZLE_RETRACT retracts and remembers the amount in the saved
  variable nozzle_retract (survives restarts, capped at 15 mm).
  PRINT_END retracts 5 mm, PRINT_WARMUP 2 mm, CANCEL_PRINT 5 mm plus the
  park/PAUSE retract.
- _NOZZLE_UNRETRACT in PRINT_START pushes it back over the bucket before
  the wipe.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-11 15:01:55 +02:00
mangavalkandClaude Opus 5.5 179bd0991b Include after AFC, link scripts/ into the config folder
- bd_pa_spoolman.cfg renames AFC's SET_SPOOL_ID, so klipper-macros.cfg
  must be included after [include AFC/*.cfg]; the README said otherwise.
- install.sh links scripts/ as ~/printer_data/config/klipper-macros-scripts
  so the scripts can be edited in Mainsail/Fluidd.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:28:52 +02:00
mangavalkandClaude Opus 5.5 9dc733b5bb Fix pause/resume chain, shared print cleanup, add CLAUDE.md
- RESUME is defined only in print/pause_resume.cfg; heat_soak.cfg's
  duplicate replaced it (no unretract, no fan restore). It now runs
  HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE.
- PAUSE runs PAUSE_BASE first, then retracts and parks once (X20 Y345);
  a parked flag makes resume undo only what PAUSE did.
- New _PRINT_CLEANUP shared by PRINT_END and CANCEL_PRINT: heaters incl.
  iHEATER_OFF, fan, M221 S100, bdwidth off, mesh and skew cleared.
  In PRINT_END it runs after RESTORE_GCODE_STATE so the flow reset sticks.
- Add CLAUDE.md and tools/effective_config.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:20:28 +02:00