Files
klipper-macros/CLAUDE.md
T
mangavalkandClaude Opus 5.5 a16b57a0a9 Move bd_pressure.cfg and TEST_SPEED into the repo
All macros now come from this repo. bd_pressure.cfg ([bdpressure bd_pa]
and the vendor PA_CALIBRATE macros) and Macros/TEST_SPEED.cfg were loose
files in ~/printer_data/config.

PA_CALIBRATE no longer sets Z back to z_current at the end: it was read
before the test ran, so a Z hop in the G28 XY (Beacon home_z_hop) would
leave Klipper believing the nozzle is lower than it is. Z is never switched
off or moved by the test, so it keeps its position without that line.
The ACC_WALL bug (read from ACCEL_TO_DECEL, always 4000) is documented,
not fixed: the cached PA values were measured at 4000.

printer.cfg must drop [include bd_pressure.cfg] and Macros/macros.cfg its
TEST_SPEED include, else the old copies (included later) still win.

Reference values from the load-check-afc branch and from the guard and
Z check tests added to CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-18 23:11:02 +02:00

111 lines
5.9 KiB
Markdown

# klipper-macros
Klipper macros, Klipper modules and scripts for one printer, installed on
the printer's Raspberry Pi with `install.sh` and updated through Moonraker.
See README.md for the user-facing description.
## The printer
Voron 2.4 350, Klipper + Moonraker + Mainsail on a Raspberry Pi 4
(`http://mainsailos.local`, Moonraker API on port 80). AFC Box Turtle with
5 lanes, Blobifier purge bucket, Beacon (Z homing and probing), Nitehawk-SB
toolboard (USB), Leviathan mainboard as USB-CAN bridge, bd_pressure
(load-check firmware, branch `load-check-extension` in
`D:\Claude\bd_pressure-load-check\bd_pressure`), bdwidth (CCD width/motion sensor on USB; switched off: its motion reading
stays at 0, its width compensation made the flow jump 77-119% and a USB
dropout once shut down Klipper. The macros work with or without
`[bdwidth fila_width_0]`; clogs and breaks are caught by AFC's buffer fault
detection, `filament_error_sensitivity`), iHeater chamber heater.
## Working with the printer
- Read freely through Moonraker: `GET /server/files/config/<path>`,
`/server/files/logs/klippy.log`, `/printer/objects/query?...`,
`/server/gcode_store`. The merged config Klipper loaded is in klippy.log
after `===== Config file =====`.
- Do **not** change anything on the printer (upload files, edit config, send
G-code, restart services) unless the user asks for that specific action.
Prepare files here and let the user upload them.
- Never run anything that moves the printer or heats while a print may be
running; check `print_stats.state` first.
## Repo layout
- `macros/klipper-macros.cfg` is the only file `printer.cfg` includes; it
includes everything else. It must be included after `[include AFC/*.cfg]`
(a `rename_existing` of an AFC command only works if AFC loaded first).
On the Pi, `macros/` is linked as `~/printer_data/config/klipper-macros/`
and `scripts/` as `~/printer_data/config/klipper-macros-scripts/`.
- `extras/*.py` are linked into `~/klipper/klippy/extras/`.
- `scripts/` MCU firmware update scripts (printer-specific IDs).
- `tools/effective_config.py` expands the includes like Klipper and compares
the result between git refs.
## Rules for macro changes
- **Never define the same `[gcode_macro X]` in two files.** Klipper merges
sections with the same name and the later file wins completely (this is
how heat_soak.cfg's RESUME silently replaced the real RESUME). Include
order in `klipper-macros.cfg` matters for this.
- `RESUME` and `PAUSE` are defined only in `print/pause_resume.cfg`. AFC
renames PAUSE/RESUME at startup and wraps them:
`PAUSE -> AFC_PAUSE -> PAUSE -> PAUSE_BASE`,
`RESUME -> AFC_RESUME -> RESUME -> HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE`.
After a PAUSE, `_RESUME_PRINT` first purges with `BLOBIFIER_CHECKED`
(`_RESUME_PURGE`); a failed check raises an error, which aborts the whole
chain (AFC_RESUME's restore too), so the printer stays paused.
- Only one `[save_variables]`, in `macros/save_variables.cfg`.
- `PRINT_END` and `CANCEL_PRINT` share `_PRINT_CLEANUP` (heaters including
`iHEATER_OFF`, fan, `M221 S100`, bdwidth off). Anything that must happen
at the end of every print goes there. `RESTORE_GCODE_STATE` restores the
flow (M221), so reset flow after it, not before.
- Do not use `G10`/`G11` in macros: Klipper's `G10` retracts only once until
a `G11`, and nothing on this printer sends `G11`. Use `_NOZZLE_RETRACT`
(remembered in the saved variable `nozzle_retract`); `PRINT_START` undoes
it over the bucket with `_NOZZLE_UNRETRACT`.
- Inside `gcode:` use `;` for comments on G-code lines; `#` lines are
stripped by the config parser. Never put a comment on an `M117` line:
M117 shows the raw rest of the line, comment included.
- Errors and warnings go through `_ERROR` / `_WARN` (`macros/messages.cfg`),
not `action_raise_error` / `RESPOND TYPE=error`, so they also show on the
display. `action_raise_error` aborts while rendering, so an `M117` in the
same macro would never run. No double quotes in `MSG`/`DISPLAY`.
- Nozzle guard (`print/nozzle_guard.cfg`, `extras/bdp_guard.py`): wrap only
moves where nothing may touch the nozzle in `_GUARD_ON PHASE=x` /
`_GUARD_OFF`. Never leave it on across contact homing, extrusion, purges,
the Blobifier park or AFC cuts and loads: in `mode: stop` that is an
instant shutdown.
- After a refactor run `python tools/effective_config.py HEAD` and check that
only the intended sections changed.
- Render-test macros with Jinja2 using Klipper's delimiters
(`jinja2.Environment('{%', '%}', '{', '}')`) and mocked `printer` objects.
## Rules for the Python modules (`extras/`)
- Klipper only loads changed `.py` files when the **Klipper service**
restarts (`sudo systemctl restart klipper`); `RESTART` and
`FIRMWARE_RESTART` keep the old code in memory.
- Event handlers must never raise: an exception in a handler shuts Klipper
down. Example: Beacon sends `homing:home_rails_end` with `rails=[]` and a
homing state whose `get_trigger_position` raises.
- Keep them read-only wrappers where possible (look up the other module's
object, do not patch third-party files).
## Reference values
- Purge check (150 mm Blobifier purge): good load = longest pressure
13-18 s, peak 64-181; empty nozzle about 30 ms. A real failed load in a
print start (AFC reported the lane loaded, nothing reached the nozzle):
longest 1915 ms, peak 45, caught by the 5000 ms limit.
- Nozzle guard (bdp_guard): reading at rest and in travel peaks about 2; a
light finger push on the cold nozzle gives 41 (threshold 30).
- Z check after a contact homing: Beacon vs Klipper Z about 0.06 mm.
- XY drift check: endstop noise about 0.01-0.02 mm; limit 0.1 mm (one motor
skipping one cycle = 0.4 mm shows as 0.2 mm in X and Y).
## Git
- LF line endings everywhere (`.gitattributes`); the files run on Linux.
- Commit only when the user says so; never push without asking. Remote: