mangavalkandClaude Opus 5.5 536db5836d Purge check: fail when bd_pressure does not answer, add override
A bd_pressure that does not answer used to be reported as "pressure
skipped" and the purge passed unchecked. It now fails the check, so in
enforce mode the printer pauses (and a resume purge stays paused).
PURGE_CHECK_IGNORE_SENSOR lets purges pass without the sensor until the
print ends; _PRINT_CLEANUP clears it so the next print checks again.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 21:18:21 +02:00

170 lines
9.3 KiB
Markdown

# klipper-macros
My Klipper macros, the small Klipper modules they need, and helper scripts,
from a Voron 2.4 (350) with an AFC Box Turtle (5 lanes), Blobifier, Beacon,
Nitehawk-SB toolboard, bd_pressure, bdwidth and an iHeater chamber heater.
Installs with one script and updates through Moonraker's update manager.
## Contents
### Macros (`macros/`)
`printer.cfg` includes only `macros/klipper-macros.cfg`; that file includes
everything below, grouped by topic. Comment out what you do not use there.
| File | Macros | Needs |
|---|---|---|
| `save_variables.cfg` | the one `[save_variables]` for all macros (file `bd_pa_variables.cfg` in the config folder) | — |
| **blobifier/** | | |
| `blobifier.cfg` | `BLOBIFIER`, `BLOBIFIER_CLEAN`, `BLOBIFIER_PARK`, `BLOBIFIER_SHAKE_BUCKET`, ...: purge bucket and nozzle brush for AFC (Turtleblobifier, heavily modified) | Blobifier hardware, AFC |
| `blobifier_hw.cfg` | servo and bucket switch pins | — |
| **print/** | | |
| `print_start_end.cfg` | `PRINT_WARMUP`, `PRINT_START`, `PRINT_END` | Beacon, AFC, Blobifier, `HEAT_SOAK`, iHeater, bd_pressure PA macros (bdwidth is no longer enabled while printing) |
| `pause_resume.cfg` | `PAUSE`, `RESUME`, `CANCEL_PRINT`, `M600` (RESUME also handles a running `HEAT_SOAK`, and after a PAUSE purges 40 mm with `BLOBIFIER_CHECKED` first: a failed check keeps the print paused, `RESUME PURGE=0` skips the purge; CANCEL_PRINT runs the same cleanup as `PRINT_END`) | `heating/heat_soak.cfg`, `leds/`, `blobifier/`, `afc/purge_check.cfg` |
| `filament.cfg` | `LOAD_FILAMENT`, `UNLOAD_FILAMENT` | — |
| `homing.cfg` | `HOME` | — |
| `idle_timeout.cfg` | `[idle_timeout]`: heaters, chamber heater and motors off | iHeater macros |
| **heating/** | | |
| `heat_soak.cfg` | `HEAT_SOAK`, `STOP_HEAT_SOAK`, `CANCEL_HEAT_SOAK`, `HEAT_SOAK_RESUME`, `RESUME` | — |
| `soak_my_bed.cfg` | `SOAK_MY_BED` (homes and levels first) | soak-my-bed |
| `bed_fans.cfg` | Bed fans through `SET_HEATER_TEMPERATURE`/`M190`/`M140`/`TURN_OFF_HEATERS` overrides | `[fan_generic BedFans]` |
| `chamber_iheater.cfg` | iHeater MCU, heater and sensors, `M141`, `M191`, `iHEATER_ON`, `iHEATER_OFF` | iHeater chamber heater |
| `filament_drying.cfg` | `START_DRYING`, `STOP_DRYING`, `STATUS_DRYING` | bed fans, chamber heater (optional) |
| **afc/** | | |
| `xy_safety_check.cfg` | `AFC_XY_SAFETY_CHECK`, `_AFC_STORE_HOME_REFERENCE`, `AFC_XY_RESUME`: lost-step check around tool changes | `extras/xy_drift.py` (CoreXY) |
| `lane_tools.cfg` | `LANE_FEED_UNTIL_HUB_OPEN`, `LANE_FEED_ABORT` | AFC |
| `purge_check.cfg` | `BLOBIFIER_CHECKED`: checks every AFC purge with bd_pressure (and optionally bdwidth motion); a bd_pressure that does not answer fails the check, `PURGE_CHECK_IGNORE_SENSOR` lets the current print finish without it | Blobifier, AFC, `extras/bdpressure_check.py` + bd_pressure load-check firmware, `extras/bdwidth_status.py` |
| `purge_until_empty.cfg` | `PURGE_UNTIL_EMPTY`: purges a snapped filament out until there is no more nozzle pressure | same as `purge_check.cfg` |
| **pressure_advance/** | | |
| `bd_pa_spoolman.cfg` + `bd_pa_*.sh` | `LANE_CALIBRATE_PA`, `PA_CALIBRATE_ALL_LANES`, `LANE_RECAL_PA`, `SET_SPOOL_ID`, `PA_STATUS`: pressure advance per lane/spool, cached locally and in Spoolman; a calibration with no result, a pause during the test or too few/stuck sensor readings is rejected and not saved | bd_pressure, AFC, Spoolman, `gcode_shell_command` |
| **spoolman/** | | |
| `active_spool.cfg` | `SET_ACTIVE_SPOOL`, `CLEAR_ACTIVE_SPOOL` | Spoolman in Moonraker |
| **leds/** | | |
| `stealthburner_leds.cfg` | Stealthburner LED effects and `_status_*` macros | `led_effect` |
| **sensors/** | | |
| `motion_sensor.cfg` | PIR motion sensor switching the case light | sensor on a pin, `[output_pin caselight]` |
### Klipper modules (`extras/`)
| File | For |
|---|---|
| `xy_drift.py` | `AFC_XY_SAFETY_CHECK`: measures lost XY steps from the stepper step counts at the endstop triggers (CoreXY). The toolhead position after homing cannot show lost steps. |
| `bdwidth_status.py` | exposes bdwidth's motion counter and width to macros (`present: False` with neutral values when no bdwidth is configured, so the macros also work without it), and keeps a USB dropout of bdwidth (port: usb) from shutting down Klipper: the read is retried every 10 s and the port reopened |
| `bdpressure_check.py` | bd_pressure load check (`BDP_CHECK_START/STOP/QUERY`). Needs the load-check firmware from the bd_pressure `load-check-extension` branch; on stock firmware it reports "not available" and does nothing. Also reports how many readings the last `PA_CALIBRATE` got (`pa_points`, `pa_distinct`), used to reject runs with a silent or stuck sensor. |
### Scripts (`scripts/`)
Firmware update scripts for all MCUs (Klipper and Katapult). They contain
this printer's CAN UUIDs and serial IDs: see [scripts/README.md](scripts/README.md)
before using them on another printer.
### Tools (`tools/`)
`effective_config.py` builds the config Klipper gets from
`klipper-macros.cfg` (includes expanded, duplicate sections merged) and
compares it between git refs, for example `python tools/effective_config.py HEAD`
after a change. `CLAUDE.md` has the notes for working on this repo with
Claude Code.
## Install
On the Klipper host:
```bash
cd ~ && git clone https://mangavalk.com/mangavalk/klipper-macros.git
~/klipper-macros/install.sh
```
`install.sh`:
- links `extras/*.py` into `~/klipper/klippy/extras/` (and hides them from
Klipper's update manager),
- links `macros/` to `~/printer_data/config/klipper-macros` and `scripts/` to
`~/printer_data/config/klipper-macros-scripts`, so the files show up in
Mainsail/Fluidd and can be edited there,
- makes the shell scripts executable,
- adds this section to `moonraker.conf` (once, with a backup):
```ini
[update_manager klipper-macros]
type: git_repo
path: ~/klipper-macros
origin: https://mangavalk.com/mangavalk/klipper-macros.git
primary_branch: main
managed_services: klipper
install_script: install.sh
```
Then:
1. In `printer.cfg`, after `[include mainsail.cfg]` **and after the AFC
includes** (`[include AFC/*.cfg]`):
```ini
[include klipper-macros/klipper-macros.cfg]
```
`bd_pa_spoolman.cfg` wraps AFC's `SET_SPOOL_ID` with `rename_existing`,
which only works when AFC is loaded first; otherwise Klipper stops with
`Existing command 'SET_SPOOL_ID' not found in gcode_macro rename`.
2. Restart the **Klipper service** (`sudo systemctl restart klipper`, or
Mainsail → services → klipper → restart). A `RESTART` or
`FIRMWARE_RESTART` does not load new or changed Python modules.
3. Restart Moonraker once, so the update manager shows `klipper-macros`.
Updates then come through Moonraker; it re-runs `install.sh` and restarts
Klipper.
## Adapting to another printer
These are the settings of one printer. Before using a file, check:
- **Names:** `fila_width_0` (bdwidth), `bd_pa` (bd_pressure), `sb_leds`,
`caselight`, `BedFans`, `iHeater_H`, lane names `lane1..lane5`.
- **Pins and serial IDs:** `blobifier/blobifier_hw.cfg` (`PC1`, `PC3`),
`sensors/motion_sensor.cfg` (`PC0`),
`heating/chamber_iheater.cfg` (serial ID).
- **Positions:** the bed centre `X175 Y175` (350 mm bed) in `print/homing.cfg`
and `print/print_start_end.cfg`.
`AFC_XY_SAFETY_CHECK` uses the axis limits from your config.
- **Settings at the top of a file** (`variable_...`): `afc/purge_check.cfg`
(`mode: "enforce"`, `motion_check: False` because this printer's bdwidth
motion reading is unreliable), `pressure_advance/bd_pa_spoolman.cfg`
(`spoolman_url`), `heating/bed_fans.cfg`, `heating/filament_drying.cfg`.
- `xy_drift.py` is for CoreXY only.
Comment out files you do not need in `klipper-macros.cfg`.
## Uninstall
```bash
~/klipper-macros/install.sh --uninstall
```
Then remove the include from `printer.cfg` and the
`[update_manager klipper-macros]` section from `moonraker.conf`, and restart
the Klipper service.
## Credits
Some files started from other projects and were modified here; their
original licenses apply to those parts:
| File | Based on |
|---|---|
| `blobifier/` | [Turtleblobifier](https://github.com/ImSundee/Turtleblobifier) (AFC version of [Dendrowen/Blobifier](https://github.com/Dendrowen/Blobifier)) |
| `leds/stealthburner_leds.cfg` | [tanaes/whopping_Voron_mods](https://github.com/tanaes/whopping_Voron_mods) (Rainbow Barf logo LEDs) |
| `heating/bed_fans.cfg` | Ellis' bed fan macros ([ellis3dp.com](https://ellis3dp.com/Print-Tuning-Guide/)) |
| `heating/heat_soak.cfg` | community `HEAT_SOAK` macro |
| `heating/chamber_iheater.cfg` | iHeater vendor configuration |
| `heating/filament_drying.cfg` | community filament drying macro |
| `print/pause_resume.cfg`, `print/filament.cfg` | [KlipperScreen recommended macros](https://klipperscreen.readthedocs.io/en/latest/macros/#recommended) |
| `scripts/` | [Voron docs: automating MCU updates](https://docs.vorondesign.com/community/howto/drachenkatze/automating_klipper_mcu_updates.html), [Esoterical's CANBus guide](https://canbus.esoterical.online/) |
Uses: [Klipper](https://github.com/Klipper3d/klipper),
[AFC-Klipper-Add-On](https://github.com/ArmoredTurtle/AFC-Klipper-Add-On),
[bd_pressure](https://github.com/markniu/bd_pressure),
[bdwidth](https://github.com/markniu/bdwidth),
[klipper-led_effect](https://github.com/julianschill/klipper-led_effect),
[soak-my-bed](https://github.com/marcofailli/soak-my-bed),
[Spoolman](https://github.com/Donkie/Spoolman).