mangavalkandClaude Opus 5.5 a63b66a7d8 bdp_guard: new zero at every ARM
With TPU in a nozzle heating to 150C the pressure kept changing for
minutes (+43, then -56 as it oozed), faster than the sensor's own
baseline update, and the guard stopped the printer at the start of
z_check and home_xy with the nozzle in the air. Every ARM (also a phase
switch) now writes reset_probe (register 52) and waits 0.2 s without
reading, so only force during the guarded moves counts.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 16:34:26 +02:00

284 lines
12 KiB
Python

# Nozzle collision guard with bd_pressure (load-check firmware extension).
#
# The bd_pressure strain gauge sees the force on the nozzle. The load-check
# firmware keeps the current force minus its baseline in register 64-65
# (chk_delta), also outside a load check; it is the same value the endstop
# output switches on (|delta| >= thrhold). While the guard is armed this
# module reads it every INTERVAL seconds. In stop mode, SAMPLES reads in a
# row at or above THRESHOLD shut Klipper down at once (like M112, without
# waiting for the running macro to finish).
#
# Every ARM (also a phase switch) first sets a new zero (register 52), so
# slow pressure changes before the guarded moves do not count (TPU in a
# nozzle that heats up keeps changing pressure for minutes).
#
# Arm it only around moves where the nozzle must not touch anything: not
# around contact homing, extrusion, purges or AFC cuts and loads, which
# press on the nozzle on purpose. ARM and DISARM act immediately, not in
# the move queue: put an M400 before them (the _GUARD_ON/_GUARD_OFF macros
# do this).
#
# Install: copy to ~/klipper/klippy/extras/bdp_guard.py and add
#
# [bdp_guard]
# sensor: bd_pa # name after "bdpressure" in [bdpressure bd_pa]
# mode: log # log: only measure; stop: shut down on a touch
# threshold: 30 # |delta| that counts as a touch
# samples: 3 # reads in a row at or above threshold
# interval: 0.02 # seconds between reads while armed
# timeout: 600 # disarm by itself when a phase runs this long
# # (a macro that failed before its DISARM)
#
# Commands:
# BDP_GUARD_ARM PHASE=<name> [MODE=log|stop] start (or switch phase)
# BDP_GUARD_DISARM stop and report the phase
# BDP_GUARD_QUERY report without stopping
#
# Each phase reports (console and klippy.log, "bdp_guard:") the reads, the
# peak |delta|, the longest run of reads at or above threshold and the
# read errors, so a log-mode print start shows what each phase normally
# measures before stop mode is switched on.
#
# Status (printer.bdp_guard): armed, mode, phase, threshold, samples, peak,
# longest_run, reads, errors, available
import logging
REG_MODE = 48 # status_clk: 7 = PA mode, 2 = probe (endstop) mode
REG_RESET_PROBE = 52 # set_normal: write 1 = take the current reading as zero
MODE_PA = 7
REG_EXT = 54 # extension marker 0xBD + version
REG_DELTA = 64 # chk_delta, int16 little-endian
EXT_MAGIC = 0xBD
MODES = ('log', 'stop')
# Klipper allows only one I2C request at a time per device: a second one
# while the first waits for its answer raises KeyError ('i2c_response', oid)
# and shuts Klipper down. The guard reads from a timer while G-code runs,
# and bdpressure.py writes the probe mode at every homing move (seen: G28
# during an armed guard), so all transfers of the sensor take this lock.
# The guard puts it on the sensor object at connect; bdpressure and
# bdpressure_check use sensor.i2c and so get it too.
class LockedI2C:
def __init__(self, i2c, mutex):
self._i2c = i2c
self._mutex = mutex
def i2c_read(self, *args, **kwargs):
with self._mutex:
return self._i2c.i2c_read(*args, **kwargs)
def i2c_write(self, *args, **kwargs):
with self._mutex:
return self._i2c.i2c_write(*args, **kwargs)
def i2c_write_wait_ack(self, *args, **kwargs):
with self._mutex:
return self._i2c.i2c_write_wait_ack(*args, **kwargs)
def i2c_transfer(self, *args, **kwargs):
with self._mutex:
return self._i2c.i2c_transfer(*args, **kwargs)
def __getattr__(self, name):
return getattr(self._i2c, name)
class BDPGuard:
def __init__(self, config):
self.printer = config.get_printer()
self.reactor = self.printer.get_reactor()
self.sensor_name = 'bdpressure ' + config.get('sensor', 'bd_pa')
self.mode = config.getchoice('mode', {m: m for m in MODES}, 'log')
self.threshold = config.getint('threshold', 30, minval=1)
self.samples = config.getint('samples', 3, minval=1)
self.interval = config.getfloat('interval', 0.02, minval=0.005)
self.timeout = config.getfloat('timeout', 600., minval=10.)
self.armed_until = 0.
self.sensor = self.i2c = None
self.available = False
self.timer = None
self.zeroing = False
self.phase_mode = self.mode
self._reset_phase('')
self.printer.register_event_handler('klippy:connect',
self._handle_connect)
self.printer.register_event_handler('klippy:shutdown',
self._handle_shutdown)
gcode = self.printer.lookup_object('gcode')
gcode.register_command('BDP_GUARD_ARM', self.cmd_ARM,
desc="Arm the bd_pressure nozzle collision guard")
gcode.register_command('BDP_GUARD_DISARM', self.cmd_DISARM,
desc="Disarm the bd_pressure nozzle collision guard")
gcode.register_command('BDP_GUARD_QUERY', self.cmd_QUERY,
desc="Report the bd_pressure guard values")
def _handle_connect(self):
self.sensor = self.printer.lookup_object(self.sensor_name, None)
i2c = getattr(self.sensor, 'i2c', None)
if i2c is not None and not isinstance(i2c, LockedI2C):
# Every user of the sensor (bdpressure, bdpressure_check, this
# guard) now goes through one lock, see LockedI2C
i2c = LockedI2C(i2c, self.reactor.mutex())
self.sensor.i2c = i2c
self.i2c = i2c
def _handle_shutdown(self):
self._stop_timer()
def _reset_phase(self, phase):
self.phase = phase
self.peak = self.longest_run = self.run = 0
self.reads = self.errors = 0
def _check_available(self):
if self.i2c is None:
return False
try:
data = bytearray(self.i2c.i2c_read([REG_EXT], 2)['response'])
except Exception:
logging.exception("bdp_guard: reading the extension marker failed")
return False
return len(data) == 2 and data[0] == EXT_MAGIC and data[1] >= 1
def _ensure_probe_mode(self, gcmd):
# An emergency stop during PA_CALIBRATE leaves the sensor in PA mode
# (FIRMWARE_RESTART does not reset it); bdpressure.py only switches
# it back at the next homing move, after the guard is armed. In PA
# mode the delta means nothing and could trip the guard. Register 48
# is the mode: 7 = PA, 2 = probe.
if getattr(self.sensor, 'last_state', 0):
return # a calibration runs, leave the sensor alone
try:
mode = bytearray(self.i2c.i2c_read([REG_MODE], 1)['response'])
if len(mode) != 1 or mode[0] != MODE_PA:
return
self.sensor.set_probe_mode()
# new samples at the probe sample rate, then a fresh baseline
self.reactor.pause(self.reactor.monotonic() + 0.5)
self.i2c.i2c_write([REG_RESET_PROBE, 1])
self.reactor.pause(self.reactor.monotonic() + 0.3)
except Exception:
logging.exception("bdp_guard: switching the sensor to probe mode failed")
return
msg = ("BDP_GUARD: bd_pressure was still in PA mode (stopped "
"calibration?), switched to probe mode")
logging.info(msg)
gcmd.respond_info(msg)
def _rezero(self):
# A fresh zero at every ARM: only force that appears during the
# guarded moves counts, not slow changes before them. Seen with TPU
# in a nozzle heating to 150C: the pressure kept rising (+43) or
# falling as it oozed (-56) for minutes, faster than the sensor's
# own baseline update (only when steady, about every 7 s), and
# stopped the printer at the start of a phase with the nozzle in
# the air. ARM comes after M400, with the nozzle clear of
# everything, so this does not hide a real touch.
self.zeroing = True
try:
self.i2c.i2c_write([REG_RESET_PROBE, 1])
self.reactor.pause(self.reactor.monotonic() + 0.2)
except Exception:
logging.exception("bdp_guard: setting a new zero failed")
self.zeroing = False
def _stop_timer(self):
if self.timer is not None:
self.reactor.unregister_timer(self.timer)
self.timer = None
def _poll(self, eventtime):
# Never raise here: an exception in a timer shuts Klipper down.
try:
if self.printer.is_shutdown():
return self.reactor.NEVER
if eventtime > self.armed_until:
logging.info("bdp_guard: %s armed longer than %.0f s, "
"disarmed (%d reads, peak %d)", self.phase,
self.timeout, self.reads, self.peak)
self._stop_timer()
self.phase = ''
return self.reactor.NEVER
# PA mode (SET_BDPRESSURE START): the delta means nothing then;
# while ARM sets a new zero the readings are in between
if self.zeroing or getattr(self.sensor, 'last_state', 0):
return eventtime + self.interval
data = bytearray(self.i2c.i2c_read([REG_DELTA], 2)['response'])
if len(data) != 2:
self.errors += 1
return eventtime + self.interval
delta = data[0] | (data[1] << 8)
if delta & 0x8000:
delta -= 0x10000
mag = abs(delta)
self.reads += 1
self.peak = max(self.peak, mag)
self.run = self.run + 1 if mag >= self.threshold else 0
self.longest_run = max(self.longest_run, self.run)
if self.run >= self.samples and self.phase_mode == 'stop':
# klippy:shutdown unregisters this timer
self.printer.invoke_shutdown(
"bd_pressure guard: nozzle touched something during %s "
"(delta %d, threshold %d)"
% (self.phase or 'an armed move', delta, self.threshold))
return self.reactor.NEVER
except Exception:
self.errors += 1
if self.errors == 1: # 50 reads/s: only the first per phase
logging.exception("bdp_guard: read failed")
return eventtime + self.interval
def _report(self, gcmd, prefix):
msg = ("%s %s (%s): %d reads, peak %d, longest run >= %d: %d reads, "
"%d errors" % (prefix, self.phase or '-', self.phase_mode,
self.reads, self.peak, self.threshold,
self.longest_run, self.errors))
logging.info("bdp_guard: %s", msg)
gcmd.respond_info(msg)
def cmd_ARM(self, gcmd):
phase = gcmd.get('PHASE', 'armed')
mode = gcmd.get('MODE', self.mode).lower()
if mode not in MODES:
raise gcmd.error("BDP_GUARD_ARM: MODE must be log or stop")
if self.timer is not None:
self._report(gcmd, "BDP_GUARD")
else:
self.available = self._check_available()
if not self.available:
gcmd.respond_info("BDP_GUARD_ARM: bd_pressure load-check "
"extension not found, guard not armed")
return
self._ensure_probe_mode(gcmd)
self._rezero()
self.phase_mode = mode
self._reset_phase(phase)
self.armed_until = self.reactor.monotonic() + self.timeout
if self.timer is None:
self.timer = self.reactor.register_timer(
self._poll, self.reactor.monotonic() + self.interval)
def cmd_DISARM(self, gcmd):
if self.timer is None:
return
self._stop_timer()
self._report(gcmd, "BDP_GUARD")
self.phase = ''
def cmd_QUERY(self, gcmd):
self._report(gcmd, "BDP_GUARD_QUERY" + (" armed" if self.timer
else " not armed"))
def get_status(self, eventtime):
return {'armed': self.timer is not None, 'mode': self.phase_mode,
'phase': self.phase, 'threshold': self.threshold,
'samples': self.samples, 'peak': self.peak,
'longest_run': self.longest_run, 'reads': self.reads,
'errors': self.errors, 'available': self.available}
def load_config(config):
return BDPGuard(config)