Commit Graph
2 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 25891640b8 Reject PA calibrations with no result or bad sensor data
bdpressure.py leaves the extruder at the last PA_CALIBRATE test value
(0.098) when it finds no result, and _PA_AFTER_CALIBRATE saved that as
the calibrated PA (lane1 after an AFC pause, lane5 after the sensor went
silent). A run is now rejected, with nothing cached or written to
Spoolman, when the PA is still at the end of the scan, the printer
paused during the test, or bd_pressure gave too few or too few different
readings. The previous valid PA (or fallback_pa) is applied instead.

bdpressure_check reports pa_points and pa_distinct from the bdpressure
module's last PA_CALIBRATE data for this.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 21:10:06 +02:00
mangavalkandClaude Opus 5.5 6dbb4ca3fb Initial import of my Klipper macros, modules and scripts
Macros as they run on the printer (Voron 2.4 + AFC Box Turtle +
Blobifier + Beacon + bd_pressure + bdwidth + iHeater), the Klipper
modules they need (xy_drift, bdwidth_status, bdpressure_check), MCU
firmware update scripts, install.sh with Moonraker update manager
support, and READMEs.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 13:45:11 +02:00