Commit Graph
5 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 1dcbc50bf6 Bed fans off during prints without a heated chamber, remove unused bed PID
With the chamber open the bed fans only blow room air past the bed. PRINT_WARMUP
sets print_fans_off for CHAMBER 30 or less, _PRINT_CLEANUP clears it. Chamber
prints, the cooldown and heating the bed outside a print are unchanged.

The PID values in PRINT_WARMUP never took effect: the SET_HEATER_TEMPERATURE
override in bed_fans.cfg only passes on the target. The bed keeps its config
values; the misleading console messages are gone.

Tested with rendered macros only, not yet on the printer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 16:18:38 +01:00
mangavalkandClaude Opus 5.5 e540e40cf7 HEAT_SOAK: resume without AFC, no trip to X0 Y0
A finished soak called RESUME, which goes through AFC_RESUME. HEAT_SOAK pauses
with PAUSE_BASE, so AFC has no saved position and restores 0,0: the toolhead
went to X0 Y0 at Z5 at up to 350 mm/s (AFC.log, 2026-11-04), and _Z_CHECK then
moved straight back. Both nozzle guard stops in z_check (delta -34 and -33)
happened in runs like this, with the toolhead front left. The exact source of
the force is unknown.

Call _RESUME_PRINT directly: it runs RESUME_BASE and skips the purge, because
PAUSE did not park. A manual Resume during a soak still goes through AFC.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-04 02:15:18 +01:00
mangavalkandClaude Opus 5.5 13e49e43c7 Bed soak on bed_side with a minimum time (measured)
Beacon meshes every 3 min on 2026-11-02 showed the 10 mm plate settles
~33 min after the bed reaches 100C with the chamber at 50C, and ~11 min at
60C with the chamber open. The old soak ended far earlier (bed_core within
5C, or the chamber reaching its target). HEAT_SOAK gets MIN_TIME=<minutes>
(default 0); PRINT_WARMUP soaks on bed_side with RATE 0.05 over 120 s,
SOAK_TEMP 70% of the bed target, MIN_TIME 35 (chamber) / 12 (no chamber),
and skips the soak without a bed target.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-02 16:58:20 +01:00
mangavalkandClaude Opus 5.5 9dc733b5bb Fix pause/resume chain, shared print cleanup, add CLAUDE.md
- RESUME is defined only in print/pause_resume.cfg; heat_soak.cfg's
  duplicate replaced it (no unretract, no fan restore). It now runs
  HEAT_SOAK_RESUME -> _RESUME_PRINT -> RESUME_BASE.
- PAUSE runs PAUSE_BASE first, then retracts and parks once (X20 Y345);
  a parked flag makes resume undo only what PAUSE did.
- New _PRINT_CLEANUP shared by PRINT_END and CANCEL_PRINT: heaters incl.
  iHEATER_OFF, fan, M221 S100, bdwidth off, mesh and skew cleared.
  In PRINT_END it runs after RESTORE_GCODE_STATE so the flow reset sticks.
- Add CLAUDE.md and tools/effective_config.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 15:20:28 +02:00
mangavalkandClaude Opus 5.5 eaf9c82617 Group macros by topic, add Blobifier, fix first tool change
- Split the macro files into folders by topic (print, heating, afc,
  pressure_advance, spoolman, leds, sensors); klipper-macros.cfg is the
  one file printer.cfg includes. Macros moved unchanged; the effective
  config is identical apart from the paths of the PA shell scripts.
- Add the modified Blobifier (Turtleblobifier for AFC) and define
  [save_variables] once in save_variables.cfg instead of in both
  blobifier.cfg and the PA macros (same file, bd_pa_variables.cfg).
- PRINT_WARMUP: heat to the loaded lane's temperature before the first
  tool change. AFC skips heating when the loaded lane's tool number is
  not in the print file's temperature list, and the unload then failed
  below min_extrude_temp.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 14:24:37 +02:00