Commit Graph
2 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 1dcbc50bf6 Bed fans off during prints without a heated chamber, remove unused bed PID
With the chamber open the bed fans only blow room air past the bed. PRINT_WARMUP
sets print_fans_off for CHAMBER 30 or less, _PRINT_CLEANUP clears it. Chamber
prints, the cooldown and heating the bed outside a print are unchanged.

The PID values in PRINT_WARMUP never took effect: the SET_HEATER_TEMPERATURE
override in bed_fans.cfg only passes on the target. The bed keeps its config
values; the misleading console messages are gone.

Tested with rendered macros only, not yet on the printer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 16:18:38 +01:00
mangavalkandClaude Opus 5.5 eaf9c82617 Group macros by topic, add Blobifier, fix first tool change
- Split the macro files into folders by topic (print, heating, afc,
  pressure_advance, spoolman, leds, sensors); klipper-macros.cfg is the
  one file printer.cfg includes. Macros moved unchanged; the effective
  config is identical apart from the paths of the PA shell scripts.
- Add the modified Blobifier (Turtleblobifier for AFC) and define
  [save_variables] once in save_variables.cfg instead of in both
  blobifier.cfg and the PA macros (same file, bd_pa_variables.cfg).
- PRINT_WARMUP: heat to the loaded lane's temperature before the first
  tool change. AFC skips heating when the loaded lane's tool number is
  not in the print file's temperature list, and the unload then failed
  below min_extrude_temp.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 14:24:37 +02:00