Commit Graph
2 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 25891640b8 Reject PA calibrations with no result or bad sensor data
bdpressure.py leaves the extruder at the last PA_CALIBRATE test value
(0.098) when it finds no result, and _PA_AFTER_CALIBRATE saved that as
the calibrated PA (lane1 after an AFC pause, lane5 after the sensor went
silent). A run is now rejected, with nothing cached or written to
Spoolman, when the PA is still at the end of the scan, the printer
paused during the test, or bd_pressure gave too few or too few different
readings. The previous valid PA (or fallback_pa) is applied instead.

bdpressure_check reports pa_points and pa_distinct from the bdpressure
module's last PA_CALIBRATE data for this.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-12 21:10:06 +02:00
mangavalkandClaude Opus 5.5 eaf9c82617 Group macros by topic, add Blobifier, fix first tool change
- Split the macro files into folders by topic (print, heating, afc,
  pressure_advance, spoolman, leds, sensors); klipper-macros.cfg is the
  one file printer.cfg includes. Macros moved unchanged; the effective
  config is identical apart from the paths of the PA shell scripts.
- Add the modified Blobifier (Turtleblobifier for AFC) and define
  [save_variables] once in save_variables.cfg instead of in both
  blobifier.cfg and the PA macros (same file, bd_pa_variables.cfg).
- PRINT_WARMUP: heat to the loaded lane's temperature before the first
  tool change. AFC skips heating when the loaded lane's tool number is
  not in the print file's temperature list, and the unload then failed
  below min_extrude_temp.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 14:24:37 +02:00