PA test at Z5, purge speed per nozzle size
- _PA_CFG.test_z (default 5): LANE_CALIBRATE_PA lowers the nozzle to this
height instead of Z0 before PA_CALIBRATE, so the test lines are extruded
in the air.
- BLOBIFIER: purge_spd_nozzle {"0.4": 150, "0.2": 75} mm/min, picked by
the pa_nozzle save variable (SET_NOZZLE); other sizes use purge_spd.
150 mm/min is about 6 mm3/s, too much for a 0.2 nozzle.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
cc533824e3
commit
319410c642
2 files changed
+14
-3
No files matched your search
@@ -205,6 +205,9 @@ variable_nozzle_test: {"0.4": {"max_volumetric": 25, "pa_step": 0.002}, "0.2": {
|
||||
# lane's material (any case) applies; the lowest of these and the nozzle's
|
||||
# flow wins.
|
||||
variable_material_max_volumetric: {"tpu": 8, "tpe": 8, "flex": 8}
|
||||
# Nozzle height (mm) for the test lines (PA_CALIBRATE keeps the current Z).
|
||||
# At 5 they are extruded in the air, clear of the bed and plate.
|
||||
variable_test_z: 5
|
||||
variable_acc_wall: 5000
|
||||
variable_travel_speed: 300
|
||||
variable_acc_to_decel_factor: 50
|
||||
@@ -476,7 +479,7 @@ gcode:
|
||||
G4 P400
|
||||
G1 X30 Y349 Z10 F3000
|
||||
G4 P400
|
||||
G1 Z0 F3000
|
||||
G1 Z{cfg.test_z} F3000
|
||||
G4 P400
|
||||
PA_CALIBRATE NOZZLE_TEMP={nozzle_temp} MAX_VOLUMETRIC={vol.max} ACC_WALL={cfg.acc_wall} TRAVEL_SPEED={cfg.travel_speed} ACC_TO_DECEL_FACTOR={cfg.acc_to_decel_factor} PA_STEP={step.pa}
|
||||
|
||||
|
||||
Reference in new issue