From 319410c64280375e62ed5d6e06612e34d6a02564 Mon Sep 17 00:00:00 2001 From: MangaValk Date: Sat, 7 Nov 2026 16:37:55 +0100 Subject: [PATCH] PA test at Z5, purge speed per nozzle size - _PA_CFG.test_z (default 5): LANE_CALIBRATE_PA lowers the nozzle to this height instead of Z0 before PA_CALIBRATE, so the test lines are extruded in the air. - BLOBIFIER: purge_spd_nozzle {"0.4": 150, "0.2": 75} mm/min, picked by the pa_nozzle save variable (SET_NOZZLE); other sizes use purge_spd. 150 mm/min is about 6 mm3/s, too much for a 0.2 nozzle. Co-Authored-By: Claude Opus 5.5 --- macros/blobifier/blobifier.cfg | 12 ++++++++++-- macros/pressure_advance/bd_pa_spoolman.cfg | 5 ++++- 2 files changed, 14 insertions(+), 3 deletions(-) diff --git a/macros/blobifier/blobifier.cfg b/macros/blobifier/blobifier.cfg index 6d3d545..1b8ae64 100644 --- a/macros/blobifier/blobifier.cfg +++ b/macros/blobifier/blobifier.cfg @@ -63,6 +63,10 @@ # if you experience excessive oozing. # variable_purge_spd: 250 #300 # Speed, in mm/min, of the purge. variable_purge_spd: 150 # Speed, in mm/min, of the purge. +# Purge speed (mm/min) per nozzle size, chosen by the save variable pa_nozzle +# (SET_NOZZLE). 150 mm/min is about 6 mm3/s, too much for a 0.2 nozzle. +# A size not listed uses purge_spd. +variable_purge_spd_nozzle: {"0.4": 150, "0.2": 75} variable_purge_temp_min: 200 # Minimum nozzle purge temperature. variable_toolhead_x: 70 # From the nozzle to the left of your toolhead variable_toolhead_y: 50 # From the nozzle to the front of your toolhead @@ -278,6 +282,10 @@ variable_shaker_arm_z: 4 gcode: + # Purge speed for the fitted nozzle (purge_spd_nozzle above) + {% set nozzle = "%g" % printer.save_variables.variables["pa_nozzle"]|default(0.4)|float %} + {% set purge_rate = purge_spd_nozzle[nozzle]|float if nozzle in purge_spd_nozzle else purge_spd|float %} + # ====================================================================================== # ==================== RECORD STATE (INCL. FANS, SPEEDS, ETC...) ======================= # ====================================================================================== @@ -444,8 +452,8 @@ gcode: {% set pulses_per_retract = (purge_per_blob / retracts_per_blob / 5)|round(0, 'ceil')|int %} {% set pulses_per_blob = (purge_per_blob / 5)|round(0, 'ceil')|int %} {% set purge_per_pulse = purge_per_blob / pulses_per_blob %} - {% set pulse_time_constant = purge_per_pulse * 0.95 / purge_spd / (purge_per_pulse * 0.95 / purge_spd + purge_per_pulse * 0.05 / 50) %} - {% set pulse_duration = purge_per_pulse / purge_spd %} + {% set pulse_time_constant = purge_per_pulse * 0.95 / purge_rate / (purge_per_pulse * 0.95 / purge_rate + purge_per_pulse * 0.05 / 50) %} + {% set pulse_duration = purge_per_pulse / purge_rate %} # Repeat the process until purge_len is reached {% for blob in range(blobs) %} diff --git a/macros/pressure_advance/bd_pa_spoolman.cfg b/macros/pressure_advance/bd_pa_spoolman.cfg index b1152f8..2edf2bb 100644 --- a/macros/pressure_advance/bd_pa_spoolman.cfg +++ b/macros/pressure_advance/bd_pa_spoolman.cfg @@ -205,6 +205,9 @@ variable_nozzle_test: {"0.4": {"max_volumetric": 25, "pa_step": 0.002}, "0.2": { # lane's material (any case) applies; the lowest of these and the nozzle's # flow wins. variable_material_max_volumetric: {"tpu": 8, "tpe": 8, "flex": 8} +# Nozzle height (mm) for the test lines (PA_CALIBRATE keeps the current Z). +# At 5 they are extruded in the air, clear of the bed and plate. +variable_test_z: 5 variable_acc_wall: 5000 variable_travel_speed: 300 variable_acc_to_decel_factor: 50 @@ -476,7 +479,7 @@ gcode: G4 P400 G1 X30 Y349 Z10 F3000 G4 P400 - G1 Z0 F3000 + G1 Z{cfg.test_z} F3000 G4 P400 PA_CALIBRATE NOZZLE_TEMP={nozzle_temp} MAX_VOLUMETRIC={vol.max} ACC_WALL={cfg.acc_wall} TRAVEL_SPEED={cfg.travel_speed} ACC_TO_DECEL_FACTOR={cfg.acc_to_decel_factor} PA_STEP={step.pa}