- Design docs: 12 V DC power supply, safety and bring-up, ESP32 interface, BOM - PSU schematic (schemdraw) and KiCad 10 carrier-board project with HV net classes - ESP32 PlatformIO firmware skeleton with HV watchdog toggle - Reference schematic of the Stern 520-5138-00 display PSU Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
3.0 KiB
Safety
About 175 V sits between the +65 V and −112 V rails. Treat every HV node as live until you have measured it.
Design measures
-
Only certified mains equipment. The 12 V brick is the only mains-connected part. Buy a certified brand (e.g. Mean Well GST36A12) from a normal retailer, not AliExpress.
-
Hardware HV watchdog. The relay on the HV modules' 12 V feed is driven through a charge pump:
GPIO21 ──┤├──── A ──►|── B ───┬───────┬──── 2N7000 gate 2N7000 drain ─► relay IN (active-low) 100nF │ 1N4148 │ │ 2N7000 source ─► GND ┴ 1N4148 ═ 10µF ▯ 100k ▲ (anode GND) │ │ GND GND GNDNode A gets a diode to GND (cathode at A), and a diode from A to B (anode at A). This rectifies the toggling signal into a DC voltage on B. A constant high or low level gives no charge.
The firmware toggles GPIO21 once per scanned row (about 2 kHz). If it crashes, or the pin sticks high or low, or the ESP32 resets, the cap discharges and the relay drops within about 1 s. A stuck row can't burn the panel. (Check the polarity of your relay module's input. Some are active-low.)
-
Fail-safe defaults. The relay is normally open. Put a 10 kΩ pull-down on the watchdog path. Pull the panel ENABLE line to its off state at the 74HCT245 input, so a booting ESP32 can't light anything.
-
Sequencing. 5 V comes up, then the ESP32 boots and starts scanning, and only then does the watchdog close the relay.
-
Fusing.
Where Fuse 12 V input 3 A Each HV module input 1 A slow-blow Each raw HV rail 100 mA fast -
Discharge. 330 kΩ bleeders on raw and regulated rails. HV-present LEDs are a hint only; always measure before you touch anything.
-
Layout.
- Put all HV parts on one side, with ≥ 3 mm clearance between HV tracks.
- Use wire and caps rated for ≥ 300 V/500 V.
- Use a keyed connector to the panel.
- Close it in a plastic enclosure with no exposed HV.
- Tie all grounds at one point.
-
Semiconductors from real distributors (Mouser, Farnell, Reichelt). Fake HV transistors are common on AliExpress.
Bring-up procedure
- Build the 5 V and 12 V side only. Check the voltages.
- Connect one HV module at a time, with no load. Set NCH6100HV #1 to 90 V and #2 to 130 V. Lock the pots with nail varnish.
- Connect the regulator section, still without the panel. Check for about +65 V, −112 V and −100 V and that the bleeders discharge them.
- Test the watchdog: stop toggling GPIO21, and the HV must drop within about 1 s.
- Map the panel's power connector against the measured rails. Get a second check (photo/label).
- First power-up with the panel: 1 kΩ in series with each HV rail and a running test pattern. Measure the current per rail, then remove the series resistors.