mangavalkandClaude Opus 5.5 6b1d20acde Let SignalRGB keep the clock awake at night
New "Wake at night" setting (prmExt.wledWakeAtNight, web UI only): while
WLED frames arrive, the night schedule is ignored and the clock runs as by
day. Night mode returns as soon as the frames time out. The manual night
toggle, radar and HA Tubes switch still win.

The field uses the former padding byte of prmExt; MAGIC_VALUE_EXT is now
0x5702 and 0x5701 settings are migrated, so existing SignalRGB settings
are kept.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-03 00:04:15 +01:00
mangavalkandClaude Opus 5.5 b40b5f680c Replace the web UI with a single-file page
The upstream jQuery page (147 KB, 3-column grid, slider values hidden,
help behind label clicks, no save feedback) is replaced by
firmware/uniclock/web/index.html: one file, no jQuery, gzipped by
web/gzip_web.py to data/index.html.gz (12 KB) before every build.

- Tabs Home / Tubes / Light / Network / System, rows with label, help
  line and control; sliders always show their value
- "Saved" / "Not saved" after each change, reverted on failure; offline
  indicator with automatic retry (the old poll stopped after one error)
- WiFi and MQTT settings only save with a Save button, then offer a
  restart; password fields are write-only
- Controls for hardware this clock lacks (alarm, radar, sensors) hidden
- Runs on sample data when opened from disk

Firmware: one serveStatic route (gzip, no-cache + ETag) replaces the
per-file routes; /getConfiguration no longer returns passwords and adds
ip, hasAlarm, hasRadar and the real cathProtMin; /getCurrentInfos adds
currentSec and mqtt state and sends "lux" instead of "lx" when there is
no sensor; /cathodeProtect and /firmwareupdate now answer.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-29 00:06:35 +01:00