A NOT FEEDING / CLOG pause during a print runs RESUME by itself after 5 s, so the lane check and the purge check decide; a failed check keeps the print paused. At most 2 per print, none within 10 min of printing of the previous one, only between _PRINT_START_FINISH and the print end. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
100 lines
5.6 KiB
INI
100 lines
5.6 KiB
INI
# Automatic resume after an AFC buffer fault ("AFC NOT FEEDING" / "CLOG DETECTED")
|
|
#
|
|
# When AFC pauses a print because the buffer stayed empty or full too long,
|
|
# PAUSE (print/pause_resume.cfg) calls _AUTO_RESUME_ARM. After `delay` seconds
|
|
# _AUTO_RESUME runs the normal RESUME: AFC clears its error, the lane check
|
|
# runs, and _RESUME_PRINT purges into the Blobifier with the purge check. A
|
|
# failed check (or lane check) stops that RESUME as usual, so the print stays
|
|
# paused and waits for you.
|
|
#
|
|
# Limits, so a real problem (tangled spool, grinding extruder, clog) is not
|
|
# hidden: at most `max_per_print` automatic resumes per print, and none when
|
|
# the previous one was less than `min_interval` minutes of printing ago. After
|
|
# that the print stays paused like before.
|
|
#
|
|
# Only between _PRINT_START_FINISH and the end of the print (`active`): a pause
|
|
# during PRINT_START or a PA test needs CLEAR_PAUSE, not RESUME.
|
|
#
|
|
# Turn off: SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=enabled VALUE=False
|
|
# (until the next restart; change `enabled` below to keep it off)
|
|
|
|
[gcode_macro _AUTO_RESUME_CFG]
|
|
description: Settings and state for the automatic resume after an AFC buffer fault
|
|
variable_enabled: True
|
|
variable_max_per_print: 2 # automatic resumes per print
|
|
variable_min_interval: 10 # minutes of printing since the previous automatic resume
|
|
variable_delay: 5 # seconds after the pause (AFC finishes its own pause first)
|
|
variable_faults: ['NOT FEEDING', 'CLOG DETECTED'] # text in AFC's error message
|
|
# State (set by the macros)
|
|
variable_active: False # True from _PRINT_START_FINISH to the end of the print
|
|
variable_count: 0 # automatic resumes in this print
|
|
variable_last_at: -1.0 # print_duration (s) of the last automatic resume, -1 = none
|
|
variable_pending: '' # fault the timer is waiting to resume from
|
|
gcode:
|
|
RESPOND MSG="Auto-resume: {'on' if enabled else 'off'}, {'active' if active else 'not active'}, {count}/{max_per_print} used in this print"
|
|
|
|
# Called by _PRINT_START_FINISH (ON=1) and _PRINT_CLEANUP (ON=0)
|
|
[gcode_macro _AUTO_RESUME_ACTIVE]
|
|
description: Start (ON=1) or end (ON=0) the automatic resume for a print
|
|
gcode:
|
|
{% set on = params.ON|default(1)|int %}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=active VALUE={True if on else False}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=count VALUE=0
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=last_at VALUE=-1.0
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="''"
|
|
UPDATE_DELAYED_GCODE ID=_AUTO_RESUME DURATION=0
|
|
{% if on and 'AFC' in printer %}
|
|
# Old messages would be read as this print's fault: start empty
|
|
AFC_CLEAR_ALL_MESSAGES
|
|
{% endif %}
|
|
|
|
# Called by PAUSE when it pauses a print. AFC's message queue shows its oldest
|
|
# message first; _RESUME_PRINT removes a buffer fault message once resumed, so
|
|
# the oldest one is this pause's.
|
|
[gcode_macro _AUTO_RESUME_ARM]
|
|
description: Start the automatic resume timer when AFC paused for a buffer fault and the limits allow it
|
|
gcode:
|
|
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
|
|
{% set has_afc = 'AFC' in printer %}
|
|
{% set msg = printer.AFC.message.message|default('') if has_afc else '' %}
|
|
{% set fault = (cfg.faults|select('in', msg)|list + [''])[0] %}
|
|
{% set now = printer.print_stats.print_duration|float %}
|
|
{% if cfg.enabled and cfg.active and has_afc and printer.AFC.error_state and fault %}
|
|
{% if cfg.count >= cfg.max_per_print %}
|
|
_WARN MSG="Auto-resume: not resuming after AFC {fault}, already {cfg.count} automatic resumes in this print. Check the lane, then RESUME." DISPLAY="AFC {fault}: check, then RESUME"
|
|
{% elif cfg.last_at >= 0 and now - cfg.last_at < cfg.min_interval * 60 %}
|
|
_WARN MSG="Auto-resume: not resuming after AFC {fault}, the last automatic resume was only {((now - cfg.last_at) / 60)|round(1)} min of printing ago. Check the lane, then RESUME." DISPLAY="AFC {fault} again: check, then RESUME"
|
|
{% else %}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="'{fault}'"
|
|
RESPOND MSG="Auto-resume: AFC {fault}, resuming in {cfg.delay} s with the purge check ({cfg.count + 1}/{cfg.max_per_print})"
|
|
UPDATE_DELAYED_GCODE ID=_AUTO_RESUME DURATION={cfg.delay}
|
|
{% endif %}
|
|
{% endif %}
|
|
|
|
[delayed_gcode _AUTO_RESUME]
|
|
gcode:
|
|
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
|
|
{% set fault = cfg.pending %}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=pending VALUE="''"
|
|
# Only when nothing changed since the pause: still paused, still AFC's
|
|
# error (a manual RESUME or CANCEL in the meantime ends it)
|
|
{% if fault and cfg.active and printer.print_stats.state == 'paused'
|
|
and printer.pause_resume.is_paused and printer.AFC.error_state %}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=count VALUE={cfg.count + 1}
|
|
SET_GCODE_VARIABLE MACRO=_AUTO_RESUME_CFG VARIABLE=last_at VALUE={printer.print_stats.print_duration|float}
|
|
RESPOND MSG="Auto-resume {cfg.count + 1}/{cfg.max_per_print} after AFC {fault}"
|
|
M117 Auto-resume {cfg.count + 1}/{cfg.max_per_print}: AFC {fault}
|
|
RESUME
|
|
{% endif %}
|
|
|
|
# Called by _RESUME_PRINT after a resume: remove a buffer fault message from
|
|
# the front of AFC's queue, so the next pause reads its own message
|
|
[gcode_macro _AUTO_RESUME_CLEAR_FAULT]
|
|
description: Helper: drop AFC's buffer fault message after a resume
|
|
gcode:
|
|
{% set cfg = printer["gcode_macro _AUTO_RESUME_CFG"] %}
|
|
{% set msg = printer.AFC.message.message|default('') if 'AFC' in printer else '' %}
|
|
{% if msg and cfg.faults|select('in', msg)|list %}
|
|
AFC_CLEAR_MESSAGE
|
|
{% endif %}
|