Motion lights outside the G-code queue (extras/motion_lights.py)
The AM312 case light and nozzle LEDs waited for long commands (heat waits, AFC loads, QGL) because [gcode_button] runs through the G-code queue. The new module reads the pin itself, keeps the timeout on a reactor timer and sets the case light with output_pin's send_async_request and the nozzle LEDs directly on the led_effect object. CASELIGHT and _LIGHTS_ON keep working; _STATUS_SHOW reads printer.motion_lights.near. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
55b04a7cef
commit
f25f348d0b
4 files changed
+269
-100
No files matched your search
@@ -172,7 +172,7 @@ layers:
|
||||
## nozzle effect ##
|
||||
###################
|
||||
|
||||
# Switched by _LIGHTS (sensors/motion_sensor.cfg)
|
||||
# Switched by [motion_lights] (sensors/motion_sensor.cfg, extras/motion_lights.py)
|
||||
[led_effect sb_nozzle_light]
|
||||
autostart: false
|
||||
frame_rate: 12
|
||||
@@ -218,7 +218,7 @@ description: Show STATE on the logo without storing it as the current status
|
||||
gcode:
|
||||
{% set state = params.STATE|lower %}
|
||||
{% set cfg = printer['gcode_macro _STATUS'] %}
|
||||
{% set near = printer['gcode_macro _LIGHTS'].near if 'gcode_macro _LIGHTS' in printer else True %}
|
||||
{% set near = printer.motion_lights.near if 'motion_lights' in printer else True %}
|
||||
{% set night = state == 'ready' and not near %}
|
||||
{% set cool = printer.heater_bed.temperature < cfg.part_ready_temp %}
|
||||
{% if state == 'ready' %}
|
||||
|
||||
Reference in new issue