diff --git a/macros/heating/heat_soak.cfg b/macros/heating/heat_soak.cfg index 4bc18eb..3a80326 100644 --- a/macros/heating/heat_soak.cfg +++ b/macros/heating/heat_soak.cfg @@ -293,8 +293,12 @@ gcode: {% if heat_soak.complete %} {heat_soak.complete} {% endif %} + # Not RESUME: that goes through AFC_RESUME, which restores AFC's saved + # position. HEAT_SOAK pauses with PAUSE_BASE, so AFC saved nothing and + # (seen 2026-11-04) sends the toolhead to X0 Y0 at up to 350 mm/s, just + # before the _Z_CHECK guard arms. {% if printer['pause_resume'].is_paused %} - RESUME + _RESUME_PRINT {% endif %} {% endif %} {% else %} diff --git a/macros/print/pause_resume.cfg b/macros/print/pause_resume.cfg index 58678e1..360864e 100644 --- a/macros/print/pause_resume.cfg +++ b/macros/print/pause_resume.cfg @@ -4,6 +4,8 @@ # PAUSE -> AFC_PAUSE (saves position, z-hop) -> this PAUSE -> PAUSE_BASE # RESUME -> AFC_RESUME -> this RESUME -> HEAT_SOAK_RESUME -> _RESUME_PRINT # -> RESUME_BASE, then AFC restores the saved position +# A finished HEAT_SOAK calls _RESUME_PRINT directly: AFC saved no position for +# its pause, so AFC_RESUME would send the toolhead to X0 Y0. # RESUME is defined only here: heating/heat_soak.cfg used to define its own, # which replaced this one completely (no unretract, no fan restore). # After a PAUSE, _RESUME_PRINT purges into the Blobifier with the purge check