Move bdpressure_check.py and bdp_guard.py to the bd_pressure repo
Both now live in the fork https://github.com/MangaValk/bd_pressure (klipper/, branch main, upstream PR markniu/bd_pressure#13), installed by its klipper/install.sh and its own Moonraker update_manager entry. The fork's bdpressure_check.py also reads the v2 firmware diagnostics. bdp_touch.py stays here. Docs and comments point to the bd_pressure repo. install.sh only links the files it has, so after this update it no longer overwrites the bd_pressure links. Run ~/bd_pressure/klipper/install.sh before updating, or the two links are left dangling. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
cd1cd7ca47
commit
dae8afac20
7 files changed
+19
-424
No files matched your search
@@ -1,283 +0,0 @@
|
||||
# Nozzle collision guard with bd_pressure (load-check firmware extension).
|
||||
#
|
||||
# The bd_pressure strain gauge sees the force on the nozzle. The load-check
|
||||
# firmware keeps the current force minus its baseline in register 64-65
|
||||
# (chk_delta), also outside a load check; it is the same value the endstop
|
||||
# output switches on (|delta| >= thrhold). While the guard is armed this
|
||||
# module reads it every INTERVAL seconds. In stop mode, SAMPLES reads in a
|
||||
# row at or above THRESHOLD shut Klipper down at once (like M112, without
|
||||
# waiting for the running macro to finish).
|
||||
#
|
||||
# Every ARM (also a phase switch) first sets a new zero (register 52), so
|
||||
# slow pressure changes before the guarded moves do not count (TPU in a
|
||||
# nozzle that heats up keeps changing pressure for minutes).
|
||||
#
|
||||
# Arm it only around moves where the nozzle must not touch anything: not
|
||||
# around contact homing, extrusion, purges or AFC cuts and loads, which
|
||||
# press on the nozzle on purpose. ARM and DISARM act immediately, not in
|
||||
# the move queue: put an M400 before them (the _GUARD_ON/_GUARD_OFF macros
|
||||
# do this).
|
||||
#
|
||||
# Install: copy to ~/klipper/klippy/extras/bdp_guard.py and add
|
||||
#
|
||||
# [bdp_guard]
|
||||
# sensor: bd_pa # name after "bdpressure" in [bdpressure bd_pa]
|
||||
# mode: log # log: only measure; stop: shut down on a touch
|
||||
# threshold: 30 # |delta| that counts as a touch
|
||||
# samples: 3 # reads in a row at or above threshold
|
||||
# interval: 0.02 # seconds between reads while armed
|
||||
# timeout: 600 # disarm by itself when a phase runs this long
|
||||
# # (a macro that failed before its DISARM)
|
||||
#
|
||||
# Commands:
|
||||
# BDP_GUARD_ARM PHASE=<name> [MODE=log|stop] start (or switch phase)
|
||||
# BDP_GUARD_DISARM stop and report the phase
|
||||
# BDP_GUARD_QUERY report without stopping
|
||||
#
|
||||
# Each phase reports (console and klippy.log, "bdp_guard:") the reads, the
|
||||
# peak |delta|, the longest run of reads at or above threshold and the
|
||||
# read errors, so a log-mode print start shows what each phase normally
|
||||
# measures before stop mode is switched on.
|
||||
#
|
||||
# Status (printer.bdp_guard): armed, mode, phase, threshold, samples, peak,
|
||||
# longest_run, reads, errors, available
|
||||
|
||||
import logging
|
||||
|
||||
REG_MODE = 48 # status_clk: 7 = PA mode, 2 = probe (endstop) mode
|
||||
REG_RESET_PROBE = 52 # set_normal: write 1 = take the current reading as zero
|
||||
MODE_PA = 7
|
||||
REG_EXT = 54 # extension marker 0xBD + version
|
||||
REG_DELTA = 64 # chk_delta, int16 little-endian
|
||||
EXT_MAGIC = 0xBD
|
||||
MODES = ('log', 'stop')
|
||||
|
||||
|
||||
# Klipper allows only one I2C request at a time per device: a second one
|
||||
# while the first waits for its answer raises KeyError ('i2c_response', oid)
|
||||
# and shuts Klipper down. The guard reads from a timer while G-code runs,
|
||||
# and bdpressure.py writes the probe mode at every homing move (seen: G28
|
||||
# during an armed guard), so all transfers of the sensor take this lock.
|
||||
# The guard puts it on the sensor object at connect; bdpressure and
|
||||
# bdpressure_check use sensor.i2c and so get it too.
|
||||
class LockedI2C:
|
||||
def __init__(self, i2c, mutex):
|
||||
self._i2c = i2c
|
||||
self._mutex = mutex
|
||||
|
||||
def i2c_read(self, *args, **kwargs):
|
||||
with self._mutex:
|
||||
return self._i2c.i2c_read(*args, **kwargs)
|
||||
|
||||
def i2c_write(self, *args, **kwargs):
|
||||
with self._mutex:
|
||||
return self._i2c.i2c_write(*args, **kwargs)
|
||||
|
||||
def i2c_write_wait_ack(self, *args, **kwargs):
|
||||
with self._mutex:
|
||||
return self._i2c.i2c_write_wait_ack(*args, **kwargs)
|
||||
|
||||
def i2c_transfer(self, *args, **kwargs):
|
||||
with self._mutex:
|
||||
return self._i2c.i2c_transfer(*args, **kwargs)
|
||||
|
||||
def __getattr__(self, name):
|
||||
return getattr(self._i2c, name)
|
||||
|
||||
|
||||
class BDPGuard:
|
||||
def __init__(self, config):
|
||||
self.printer = config.get_printer()
|
||||
self.reactor = self.printer.get_reactor()
|
||||
self.sensor_name = 'bdpressure ' + config.get('sensor', 'bd_pa')
|
||||
self.mode = config.getchoice('mode', {m: m for m in MODES}, 'log')
|
||||
self.threshold = config.getint('threshold', 30, minval=1)
|
||||
self.samples = config.getint('samples', 3, minval=1)
|
||||
self.interval = config.getfloat('interval', 0.02, minval=0.005)
|
||||
self.timeout = config.getfloat('timeout', 600., minval=10.)
|
||||
self.armed_until = 0.
|
||||
self.sensor = self.i2c = None
|
||||
self.available = False
|
||||
self.timer = None
|
||||
self.zeroing = False
|
||||
self.phase_mode = self.mode
|
||||
self._reset_phase('')
|
||||
self.printer.register_event_handler('klippy:connect',
|
||||
self._handle_connect)
|
||||
self.printer.register_event_handler('klippy:shutdown',
|
||||
self._handle_shutdown)
|
||||
gcode = self.printer.lookup_object('gcode')
|
||||
gcode.register_command('BDP_GUARD_ARM', self.cmd_ARM,
|
||||
desc="Arm the bd_pressure nozzle collision guard")
|
||||
gcode.register_command('BDP_GUARD_DISARM', self.cmd_DISARM,
|
||||
desc="Disarm the bd_pressure nozzle collision guard")
|
||||
gcode.register_command('BDP_GUARD_QUERY', self.cmd_QUERY,
|
||||
desc="Report the bd_pressure guard values")
|
||||
|
||||
def _handle_connect(self):
|
||||
self.sensor = self.printer.lookup_object(self.sensor_name, None)
|
||||
i2c = getattr(self.sensor, 'i2c', None)
|
||||
if i2c is not None and not isinstance(i2c, LockedI2C):
|
||||
# Every user of the sensor (bdpressure, bdpressure_check, this
|
||||
# guard) now goes through one lock, see LockedI2C
|
||||
i2c = LockedI2C(i2c, self.reactor.mutex())
|
||||
self.sensor.i2c = i2c
|
||||
self.i2c = i2c
|
||||
|
||||
def _handle_shutdown(self):
|
||||
self._stop_timer()
|
||||
|
||||
def _reset_phase(self, phase):
|
||||
self.phase = phase
|
||||
self.peak = self.longest_run = self.run = 0
|
||||
self.reads = self.errors = 0
|
||||
|
||||
def _check_available(self):
|
||||
if self.i2c is None:
|
||||
return False
|
||||
try:
|
||||
data = bytearray(self.i2c.i2c_read([REG_EXT], 2)['response'])
|
||||
except Exception:
|
||||
logging.exception("bdp_guard: reading the extension marker failed")
|
||||
return False
|
||||
return len(data) == 2 and data[0] == EXT_MAGIC and data[1] >= 1
|
||||
|
||||
def _ensure_probe_mode(self, gcmd):
|
||||
# An emergency stop during PA_CALIBRATE leaves the sensor in PA mode
|
||||
# (FIRMWARE_RESTART does not reset it); bdpressure.py only switches
|
||||
# it back at the next homing move, after the guard is armed. In PA
|
||||
# mode the delta means nothing and could trip the guard. Register 48
|
||||
# is the mode: 7 = PA, 2 = probe.
|
||||
if getattr(self.sensor, 'last_state', 0):
|
||||
return # a calibration runs, leave the sensor alone
|
||||
try:
|
||||
mode = bytearray(self.i2c.i2c_read([REG_MODE], 1)['response'])
|
||||
if len(mode) != 1 or mode[0] != MODE_PA:
|
||||
return
|
||||
self.sensor.set_probe_mode()
|
||||
# new samples at the probe sample rate, then a fresh baseline
|
||||
self.reactor.pause(self.reactor.monotonic() + 0.5)
|
||||
self.i2c.i2c_write([REG_RESET_PROBE, 1])
|
||||
self.reactor.pause(self.reactor.monotonic() + 0.3)
|
||||
except Exception:
|
||||
logging.exception("bdp_guard: switching the sensor to probe mode failed")
|
||||
return
|
||||
msg = ("BDP_GUARD: bd_pressure was still in PA mode (stopped "
|
||||
"calibration?), switched to probe mode")
|
||||
logging.info(msg)
|
||||
gcmd.respond_info(msg)
|
||||
|
||||
def _rezero(self):
|
||||
# A fresh zero at every ARM: only force that appears during the
|
||||
# guarded moves counts, not slow changes before them. Seen with TPU
|
||||
# in a nozzle heating to 150C: the pressure kept rising (+43) or
|
||||
# falling as it oozed (-56) for minutes, faster than the sensor's
|
||||
# own baseline update (only when steady, about every 7 s), and
|
||||
# stopped the printer at the start of a phase with the nozzle in
|
||||
# the air. ARM comes after M400, with the nozzle clear of
|
||||
# everything, so this does not hide a real touch.
|
||||
self.zeroing = True
|
||||
try:
|
||||
self.i2c.i2c_write([REG_RESET_PROBE, 1])
|
||||
self.reactor.pause(self.reactor.monotonic() + 0.2)
|
||||
except Exception:
|
||||
logging.exception("bdp_guard: setting a new zero failed")
|
||||
self.zeroing = False
|
||||
|
||||
def _stop_timer(self):
|
||||
if self.timer is not None:
|
||||
self.reactor.unregister_timer(self.timer)
|
||||
self.timer = None
|
||||
|
||||
def _poll(self, eventtime):
|
||||
# Never raise here: an exception in a timer shuts Klipper down.
|
||||
try:
|
||||
if self.printer.is_shutdown():
|
||||
return self.reactor.NEVER
|
||||
if eventtime > self.armed_until:
|
||||
logging.info("bdp_guard: %s armed longer than %.0f s, "
|
||||
"disarmed (%d reads, peak %d)", self.phase,
|
||||
self.timeout, self.reads, self.peak)
|
||||
self._stop_timer()
|
||||
self.phase = ''
|
||||
return self.reactor.NEVER
|
||||
# PA mode (SET_BDPRESSURE START): the delta means nothing then;
|
||||
# while ARM sets a new zero the readings are in between
|
||||
if self.zeroing or getattr(self.sensor, 'last_state', 0):
|
||||
return eventtime + self.interval
|
||||
data = bytearray(self.i2c.i2c_read([REG_DELTA], 2)['response'])
|
||||
if len(data) != 2:
|
||||
self.errors += 1
|
||||
return eventtime + self.interval
|
||||
delta = data[0] | (data[1] << 8)
|
||||
if delta & 0x8000:
|
||||
delta -= 0x10000
|
||||
mag = abs(delta)
|
||||
self.reads += 1
|
||||
self.peak = max(self.peak, mag)
|
||||
self.run = self.run + 1 if mag >= self.threshold else 0
|
||||
self.longest_run = max(self.longest_run, self.run)
|
||||
if self.run >= self.samples and self.phase_mode == 'stop':
|
||||
# klippy:shutdown unregisters this timer
|
||||
self.printer.invoke_shutdown(
|
||||
"bd_pressure guard: nozzle touched something during %s "
|
||||
"(delta %d, threshold %d)"
|
||||
% (self.phase or 'an armed move', delta, self.threshold))
|
||||
return self.reactor.NEVER
|
||||
except Exception:
|
||||
self.errors += 1
|
||||
if self.errors == 1: # 50 reads/s: only the first per phase
|
||||
logging.exception("bdp_guard: read failed")
|
||||
return eventtime + self.interval
|
||||
|
||||
def _report(self, gcmd, prefix):
|
||||
msg = ("%s %s (%s): %d reads, peak %d, longest run >= %d: %d reads, "
|
||||
"%d errors" % (prefix, self.phase or '-', self.phase_mode,
|
||||
self.reads, self.peak, self.threshold,
|
||||
self.longest_run, self.errors))
|
||||
logging.info("bdp_guard: %s", msg)
|
||||
gcmd.respond_info(msg)
|
||||
|
||||
def cmd_ARM(self, gcmd):
|
||||
phase = gcmd.get('PHASE', 'armed')
|
||||
mode = gcmd.get('MODE', self.mode).lower()
|
||||
if mode not in MODES:
|
||||
raise gcmd.error("BDP_GUARD_ARM: MODE must be log or stop")
|
||||
if self.timer is not None:
|
||||
self._report(gcmd, "BDP_GUARD")
|
||||
else:
|
||||
self.available = self._check_available()
|
||||
if not self.available:
|
||||
gcmd.respond_info("BDP_GUARD_ARM: bd_pressure load-check "
|
||||
"extension not found, guard not armed")
|
||||
return
|
||||
self._ensure_probe_mode(gcmd)
|
||||
self._rezero()
|
||||
self.phase_mode = mode
|
||||
self._reset_phase(phase)
|
||||
self.armed_until = self.reactor.monotonic() + self.timeout
|
||||
if self.timer is None:
|
||||
self.timer = self.reactor.register_timer(
|
||||
self._poll, self.reactor.monotonic() + self.interval)
|
||||
|
||||
def cmd_DISARM(self, gcmd):
|
||||
if self.timer is None:
|
||||
return
|
||||
self._stop_timer()
|
||||
self._report(gcmd, "BDP_GUARD")
|
||||
self.phase = ''
|
||||
|
||||
def cmd_QUERY(self, gcmd):
|
||||
self._report(gcmd, "BDP_GUARD_QUERY" + (" armed" if self.timer
|
||||
else " not armed"))
|
||||
|
||||
def get_status(self, eventtime):
|
||||
return {'armed': self.timer is not None, 'mode': self.phase_mode,
|
||||
'phase': self.phase, 'threshold': self.threshold,
|
||||
'samples': self.samples, 'peak': self.peak,
|
||||
'longest_run': self.longest_run, 'reads': self.reads,
|
||||
'errors': self.errors, 'available': self.available}
|
||||
|
||||
|
||||
def load_config(config):
|
||||
return BDPGuard(config)
|
||||
@@ -1,130 +0,0 @@
|
||||
# Load check using the bd_pressure firmware extension (bdp_check_ext.patch).
|
||||
#
|
||||
# Uses the I2C connection the existing [bdpressure <name>] section already
|
||||
# set up. Before writing anything it reads the extension marker (bytes
|
||||
# 54-55 = 0xBD + version 1 or 2). On stock firmware the marker is missing and every
|
||||
# command only reports "not available": nothing is written, because
|
||||
# writing past the stock register table would land in the sensor's RAM.
|
||||
#
|
||||
# Install: copy to ~/klipper/klippy/extras/bdpressure_check.py
|
||||
#
|
||||
# Config:
|
||||
# [bdpressure_check]
|
||||
# sensor: bd_pa # name after "bdpressure" in [bdpressure bd_pa]
|
||||
#
|
||||
# Commands (run them after M400, they act immediately, not in the move queue):
|
||||
# BDP_CHECK_START freeze the baseline and start measuring
|
||||
# BDP_CHECK_STOP stop measuring and read the result
|
||||
# BDP_CHECK_QUERY read the current values without stopping
|
||||
#
|
||||
# Status (printer.bdpressure_check), updated by the commands above:
|
||||
# available, running, peak, above_ms, longest_ms, delta
|
||||
# pa_points, pa_distinct - readings the [bdpressure] module collected in
|
||||
# its last PA_CALIBRATE, and how many of them differ (read
|
||||
# from that module, not from the sensor). A sensor that
|
||||
# stops answering gives few points; one that hangs repeats
|
||||
# the same reading. LANE_CALIBRATE_PA rejects such runs.
|
||||
|
||||
REG_EXT = 54 # first byte of the extension
|
||||
REG_CTRL = 56
|
||||
EXT_LEN = 12 # bytes 54-65, the same in version 1 and 2
|
||||
EXT_MAGIC = 0xBD
|
||||
# Version 2 (load-check firmware 20261015 and later) only adds diagnostics
|
||||
# at 66-71. Accepting only version 1 made the purge check report the sensor
|
||||
# as not answering after the firmware update.
|
||||
EXT_VERSIONS = (1, 2)
|
||||
|
||||
|
||||
class BDPressureCheck:
|
||||
def __init__(self, config):
|
||||
self.printer = config.get_printer()
|
||||
self.sensor_name = 'bdpressure ' + config.get('sensor', 'bd_pa')
|
||||
self.sensor = None
|
||||
self.status = {'available': False, 'running': False, 'peak': 0,
|
||||
'above_ms': 0, 'longest_ms': 0, 'delta': 0}
|
||||
self.printer.register_event_handler('klippy:connect',
|
||||
self._handle_connect)
|
||||
gcode = self.printer.lookup_object('gcode')
|
||||
gcode.register_command('BDP_CHECK_START', self.cmd_START,
|
||||
desc="Start a bd_pressure load check")
|
||||
gcode.register_command('BDP_CHECK_STOP', self.cmd_STOP,
|
||||
desc="Stop the bd_pressure load check and read it")
|
||||
gcode.register_command('BDP_CHECK_QUERY', self.cmd_QUERY,
|
||||
desc="Read the bd_pressure load check values")
|
||||
|
||||
def _handle_connect(self):
|
||||
self.sensor = self.printer.lookup_object(self.sensor_name)
|
||||
|
||||
@property
|
||||
def i2c(self):
|
||||
# Looked up at every use: bdp_guard replaces the sensor's i2c with a
|
||||
# locked wrapper at connect, possibly after this module's connect.
|
||||
return getattr(self.sensor, 'i2c', None)
|
||||
|
||||
def _read(self):
|
||||
if self.i2c is None:
|
||||
self.status['available'] = False
|
||||
return False
|
||||
data = bytearray(self.i2c.i2c_read([REG_EXT], EXT_LEN)['response'])
|
||||
if (len(data) < EXT_LEN or data[0] != EXT_MAGIC
|
||||
or data[1] not in EXT_VERSIONS):
|
||||
self.status['available'] = False
|
||||
return False
|
||||
u16 = lambda i: data[i] | (data[i + 1] << 8)
|
||||
delta = u16(10)
|
||||
self.status.update({
|
||||
'available': True,
|
||||
'running': bool(data[3] & 1),
|
||||
'peak': u16(4),
|
||||
'above_ms': u16(6),
|
||||
'longest_ms': u16(8),
|
||||
'delta': delta - 0x10000 if delta & 0x8000 else delta,
|
||||
})
|
||||
return True
|
||||
|
||||
def _respond(self, gcmd, prefix):
|
||||
s = self.status
|
||||
if not s['available']:
|
||||
gcmd.respond_info("%s: bd_pressure check extension not found "
|
||||
"(stock firmware?), nothing done" % prefix)
|
||||
return
|
||||
gcmd.respond_info("%s: running=%d peak=%d above=%d ms longest=%d ms "
|
||||
"delta=%d" % (prefix, s['running'], s['peak'],
|
||||
s['above_ms'], s['longest_ms'],
|
||||
s['delta']))
|
||||
|
||||
def cmd_START(self, gcmd):
|
||||
# The values read here are still the previous check's, so only
|
||||
# confirm the start instead of printing them.
|
||||
if self._read():
|
||||
self.i2c.i2c_write([REG_CTRL, 1])
|
||||
self.status.update({'running': True, 'peak': 0, 'above_ms': 0,
|
||||
'longest_ms': 0})
|
||||
gcmd.respond_info("BDP_CHECK_START: started")
|
||||
return
|
||||
self._respond(gcmd, "BDP_CHECK_START")
|
||||
|
||||
def cmd_STOP(self, gcmd):
|
||||
if self._read():
|
||||
self.i2c.i2c_write([REG_CTRL, 0])
|
||||
self._read()
|
||||
self._respond(gcmd, "BDP_CHECK_STOP")
|
||||
|
||||
def cmd_QUERY(self, gcmd):
|
||||
self._read()
|
||||
self._respond(gcmd, "BDP_CHECK_QUERY")
|
||||
|
||||
def get_status(self, eventtime):
|
||||
status = dict(self.status)
|
||||
# [val, res, lk, rk, Hk, Ha] per reading, see bdpressure.py
|
||||
try:
|
||||
data = list(getattr(self.sensor, 'PA_data', None) or [])
|
||||
status['pa_points'] = len(data)
|
||||
status['pa_distinct'] = len(set(tuple(d[1:]) for d in data))
|
||||
except Exception:
|
||||
status['pa_points'] = status['pa_distinct'] = -1
|
||||
return status
|
||||
|
||||
|
||||
def load_config(config):
|
||||
return BDPressureCheck(config)
|
||||
Reference in new issue