PA test: AFC buffer fault detection at 2 during PA_CALIBRATE
At the configured 8 the buffer faults after 30 mm in one state; during the test lines it needs far more to reach its other sensor, so every lane1 calibration on 2026-11-07 paused with AFC NOT FEEDING. With detection off the buffer switched after ~80 s and the test finished. _PA_CFG.test_error_sensitivity (2) is set before PA_CALIBRATE and the [AFC_buffer] config value is restored after it through _FIRST_LAYER_FAULT_DETECTION ON=0 (lowered=True), which _PRINT_CLEANUP also calls when the test stops with an error. Nothing changes when detection is off in the config. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
319410c642
commit
cd1cd7ca47
1 file changed
+21
@@ -208,6 +208,13 @@ variable_material_max_volumetric: {"tpu": 8, "tpe": 8, "flex": 8}
|
||||
# Nozzle height (mm) for the test lines (PA_CALIBRATE keeps the current Z).
|
||||
# At 5 they are extruded in the air, clear of the bed and plate.
|
||||
variable_test_z: 5
|
||||
# AFC buffer fault detection during the test lines (0-10, 0 = off). At the
|
||||
# normal 8 the buffer faults after 30 mm in one state, and during the test it
|
||||
# needs far more to reach its other sensor (2026-11-07: ~80 s for the first
|
||||
# change), so every test paused with AFC NOT FEEDING. 2 still catches a lane
|
||||
# that stops feeding. Restored to the [AFC_buffer] config value after
|
||||
# PA_CALIBRATE, or by _PRINT_CLEANUP if the test stops with an error.
|
||||
variable_test_error_sensitivity: 2
|
||||
variable_acc_wall: 5000
|
||||
variable_travel_speed: 300
|
||||
variable_acc_to_decel_factor: 50
|
||||
@@ -481,7 +488,21 @@ gcode:
|
||||
G4 P400
|
||||
G1 Z{cfg.test_z} F3000
|
||||
G4 P400
|
||||
# Buffer fault detection for the test (see test_error_sensitivity).
|
||||
# lowered=True lets _FIRST_LAYER_FAULT_DETECTION ON=0 restore it,
|
||||
# here and in _PRINT_CLEANUP when the test stops with an error.
|
||||
{% set fl = printer["gcode_macro _FIRST_LAYER_FAULT_DETECTION"] %}
|
||||
{% set buf_key = "afc_buffer " ~ fl.buffer|lower %}
|
||||
{% set normal_sens = printer.configfile.settings[buf_key].filament_error_sensitivity|default(0)|float if buf_key in printer.configfile.settings else 0 %}
|
||||
{% set lower_sens = normal_sens > 0 and cfg.test_error_sensitivity|float != normal_sens %}
|
||||
{% if lower_sens %}
|
||||
AFC_SET_ERROR_SENSITIVITY BUFFER={fl.buffer} SENSITIVITY={cfg.test_error_sensitivity}
|
||||
SET_GCODE_VARIABLE MACRO=_FIRST_LAYER_FAULT_DETECTION VARIABLE=lowered VALUE=True
|
||||
{% endif %}
|
||||
PA_CALIBRATE NOZZLE_TEMP={nozzle_temp} MAX_VOLUMETRIC={vol.max} ACC_WALL={cfg.acc_wall} TRAVEL_SPEED={cfg.travel_speed} ACC_TO_DECEL_FACTOR={cfg.acc_to_decel_factor} PA_STEP={step.pa}
|
||||
{% if lower_sens %}
|
||||
_FIRST_LAYER_FAULT_DETECTION ON=0
|
||||
{% endif %}
|
||||
|
||||
# IMPORTANT: we do NOT read printer.extruder.pressure_advance
|
||||
# here. Klipper fully evaluates a macro's Jinja2 template
|
||||
|
||||
Reference in new issue
Block a user