PA values per nozzle: SET_NOZZLE, slicer check, no Spoolman write
A PA value only holds for the nozzle it was measured with, so values are saved per nozzle and spool (pa_value_0_4_spool_<id>). SET_NOZZLE sets the fitted size; a different NOZZLE= from the slicer on PRINT_WARMUP stops the print before anything heats. The existing values are copied to 0.4 once at the first start; the old variables stay in the file, unread. Each nozzle has its own test flow and PA range (0.2: 5 mm3/s, 0-0.196, starting estimates, about 9 min a lane). The test primes at the test flow instead of 120 mm3/s. Remove the Spoolman write: it went to localhost and never arrived, and nothing read the values back. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
1dcbc50bf6
commit
b415cbebf4
7 files changed
+108
-133
No files matched your search
@@ -117,7 +117,9 @@ gcode:
|
||||
G21
|
||||
M83
|
||||
M109 S{NOZZLE_TEMP}
|
||||
G1 E4
|
||||
# At the test flow. Without F this ran at the speed of the move before
|
||||
# (F3000 in LANE_CALIBRATE_PA: 120 mm3/s), too much for a small nozzle.
|
||||
G1 E4 F{MAX_VOLUMETRIC / 2.405 * 60}
|
||||
SET_PRESSURE_ADVANCE ADVANCE=0.04; Override pressure advance value
|
||||
SET_VELOCITY_LIMIT ACCEL={ACC_WALL} ACCEL_TO_DECEL={ACC_TO_DEC}
|
||||
SET_VELOCITY_LIMIT ACCEL={ACC_WALL} MINIMUM_CRUISE_RATIO={MIN_CRUISE}
|
||||
|
||||
Reference in new issue
Block a user