PA values per nozzle: SET_NOZZLE, slicer check, no Spoolman write

A PA value only holds for the nozzle it was measured with, so values are
saved per nozzle and spool (pa_value_0_4_spool_<id>). SET_NOZZLE sets the
fitted size; a different NOZZLE= from the slicer on PRINT_WARMUP stops the
print before anything heats. The existing values are copied to 0.4 once at
the first start; the old variables stay in the file, unread.

Each nozzle has its own test flow and PA range (0.2: 5 mm3/s, 0-0.196,
starting estimates, about 9 min a lane). The test primes at the test flow
instead of 120 mm3/s.

Remove the Spoolman write: it went to localhost and never arrived, and
nothing read the values back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
mangavalkandClaude Opus 5.5 committed 2026-11-06 19:49:25 +01:00
1 parent 1dcbc50bf6
commit b415cbebf4
7 files changed
+108 -133

No files matched your search

+2 -2
View File
@@ -42,7 +42,7 @@ everything below, grouped by topic. Comment out what you do not use there.
| `purge_until_empty.cfg` | `PURGE_UNTIL_EMPTY`: purges a snapped filament out until there is no more nozzle pressure | same as `purge_check.cfg` |
| **pressure_advance/** | | |
| `bd_pressure.cfg` | `[bdpressure bd_pa]` (I2C on the Nitehawk) and the vendor macros `PA_CALIBRATE`, `PA_E`, `PA_RESET`, `PA_STATE`; `PA_CALIBRATE` no longer sets Z back to a value read before the test (wrong after a Z hop in `G28 XY`) | `bdpressure.py` from the bd_pressure repo |
| `bd_pa_spoolman.cfg` + `bd_pa_*.sh` | `LANE_CALIBRATE_PA`, `PA_CALIBRATE_ALL_LANES`, `LANE_RECAL_PA`, `SET_SPOOL_ID`, `PA_STATUS`: pressure advance per lane/spool, cached locally and in Spoolman; before a calibration the lane's spool is assigned again so a temperature just changed in Spoolman is used; flexible materials (TPU/TPE) calibrate at a lower flow (8 mm³/s) and over a wider PA range (0–0.196 in 0.004 steps instead of 0–0.098); a calibration with no result, a pause during the test or too few/stuck sensor readings is rejected and not saved | bd_pressure, AFC, Spoolman, `gcode_shell_command` |
| `bd_pa_spoolman.cfg` | `LANE_CALIBRATE_PA`, `PA_CALIBRATE_ALL_LANES`, `LANE_RECAL_PA`, `SET_SPOOL_ID`, `PA_STATUS`, `SET_NOZZLE`: pressure advance per nozzle and spool, saved on the printer; run `SET_NOZZLE SIZE=0.2` after a swap (a print start stops if the slicer profile has another size); each nozzle has its own test flow and PA range (0.4: 25 mm³/s, 0–0.098, about 2 min a lane; 0.2: 5 mm³/s, 0–0.196, about 9 min, not measured yet); before a calibration the lane's spool is assigned again so a temperature just changed in Spoolman is used; flexible materials (TPU/TPE) calibrate at a lower flow (8 mm³/s) and over a wider PA range (0–0.196 in 0.004 steps instead of 0–0.098); a calibration with no result, a pause during the test or too few/stuck sensor readings is rejected and not saved | bd_pressure, AFC, Spoolman through AFC |
| **spoolman/** | | |
| `active_spool.cfg` | `SET_ACTIVE_SPOOL`, `CLEAR_ACTIVE_SPOOL` | Spoolman in Moonraker |
| **leds/** | | |
@@ -143,7 +143,7 @@ These are the settings of one printer. Before using a file, check:
- **Settings at the top of a file** (`variable_...`): `afc/purge_check.cfg`
(`mode: "enforce"`, `motion_check: False` because this printer's bdwidth
motion reading is unreliable), `pressure_advance/bd_pa_spoolman.cfg`
(`spoolman_url`), `heating/bed_fans.cfg`, `heating/filament_drying.cfg`.
(`nozzle_test`), `heating/bed_fans.cfg`, `heating/filament_drying.cfg`.
- `xy_drift.py` is for CoreXY only.
Comment out files you do not need in `klipper-macros.cfg`.