bdp_guard: new zero at every ARM
With TPU in a nozzle heating to 150C the pressure kept changing for minutes (+43, then -56 as it oozed), faster than the sensor's own baseline update, and the guard stopped the printer at the start of z_check and home_xy with the nozzle in the air. Every ARM (also a phase switch) now writes reset_probe (register 52) and waits 0.2 s without reading, so only force during the guarded moves counts. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
29604b2f1e
commit
a63b66a7d8
1 file changed
+26
-2
+26
-2
@@ -8,6 +8,10 @@
|
|||||||
# row at or above THRESHOLD shut Klipper down at once (like M112, without
|
# row at or above THRESHOLD shut Klipper down at once (like M112, without
|
||||||
# waiting for the running macro to finish).
|
# waiting for the running macro to finish).
|
||||||
#
|
#
|
||||||
|
# Every ARM (also a phase switch) first sets a new zero (register 52), so
|
||||||
|
# slow pressure changes before the guarded moves do not count (TPU in a
|
||||||
|
# nozzle that heats up keeps changing pressure for minutes).
|
||||||
|
#
|
||||||
# Arm it only around moves where the nozzle must not touch anything: not
|
# Arm it only around moves where the nozzle must not touch anything: not
|
||||||
# around contact homing, extrusion, purges or AFC cuts and loads, which
|
# around contact homing, extrusion, purges or AFC cuts and loads, which
|
||||||
# press on the nozzle on purpose. ARM and DISARM act immediately, not in
|
# press on the nozzle on purpose. ARM and DISARM act immediately, not in
|
||||||
@@ -95,6 +99,7 @@ class BDPGuard:
|
|||||||
self.sensor = self.i2c = None
|
self.sensor = self.i2c = None
|
||||||
self.available = False
|
self.available = False
|
||||||
self.timer = None
|
self.timer = None
|
||||||
|
self.zeroing = False
|
||||||
self.phase_mode = self.mode
|
self.phase_mode = self.mode
|
||||||
self._reset_phase('')
|
self._reset_phase('')
|
||||||
self.printer.register_event_handler('klippy:connect',
|
self.printer.register_event_handler('klippy:connect',
|
||||||
@@ -162,6 +167,23 @@ class BDPGuard:
|
|||||||
logging.info(msg)
|
logging.info(msg)
|
||||||
gcmd.respond_info(msg)
|
gcmd.respond_info(msg)
|
||||||
|
|
||||||
|
def _rezero(self):
|
||||||
|
# A fresh zero at every ARM: only force that appears during the
|
||||||
|
# guarded moves counts, not slow changes before them. Seen with TPU
|
||||||
|
# in a nozzle heating to 150C: the pressure kept rising (+43) or
|
||||||
|
# falling as it oozed (-56) for minutes, faster than the sensor's
|
||||||
|
# own baseline update (only when steady, about every 7 s), and
|
||||||
|
# stopped the printer at the start of a phase with the nozzle in
|
||||||
|
# the air. ARM comes after M400, with the nozzle clear of
|
||||||
|
# everything, so this does not hide a real touch.
|
||||||
|
self.zeroing = True
|
||||||
|
try:
|
||||||
|
self.i2c.i2c_write([REG_RESET_PROBE, 1])
|
||||||
|
self.reactor.pause(self.reactor.monotonic() + 0.2)
|
||||||
|
except Exception:
|
||||||
|
logging.exception("bdp_guard: setting a new zero failed")
|
||||||
|
self.zeroing = False
|
||||||
|
|
||||||
def _stop_timer(self):
|
def _stop_timer(self):
|
||||||
if self.timer is not None:
|
if self.timer is not None:
|
||||||
self.reactor.unregister_timer(self.timer)
|
self.reactor.unregister_timer(self.timer)
|
||||||
@@ -179,8 +201,9 @@ class BDPGuard:
|
|||||||
self._stop_timer()
|
self._stop_timer()
|
||||||
self.phase = ''
|
self.phase = ''
|
||||||
return self.reactor.NEVER
|
return self.reactor.NEVER
|
||||||
# PA mode (SET_BDPRESSURE START): the delta means nothing then
|
# PA mode (SET_BDPRESSURE START): the delta means nothing then;
|
||||||
if getattr(self.sensor, 'last_state', 0):
|
# while ARM sets a new zero the readings are in between
|
||||||
|
if self.zeroing or getattr(self.sensor, 'last_state', 0):
|
||||||
return eventtime + self.interval
|
return eventtime + self.interval
|
||||||
data = bytearray(self.i2c.i2c_read([REG_DELTA], 2)['response'])
|
data = bytearray(self.i2c.i2c_read([REG_DELTA], 2)['response'])
|
||||||
if len(data) != 2:
|
if len(data) != 2:
|
||||||
@@ -229,6 +252,7 @@ class BDPGuard:
|
|||||||
"extension not found, guard not armed")
|
"extension not found, guard not armed")
|
||||||
return
|
return
|
||||||
self._ensure_probe_mode(gcmd)
|
self._ensure_probe_mode(gcmd)
|
||||||
|
self._rezero()
|
||||||
self.phase_mode = mode
|
self.phase_mode = mode
|
||||||
self._reset_phase(phase)
|
self._reset_phase(phase)
|
||||||
self.armed_until = self.reactor.monotonic() + self.timeout
|
self.armed_until = self.reactor.monotonic() + self.timeout
|
||||||
|
|||||||
Reference in new issue