PA calibration reads Spoolman first; guard resets a sensor left in PA mode
- LANE_CALIBRATE_PA: when a calibration will run, assign the lane's spool again (SET_SPOOL_ID) so AFC reads the Spoolman temperature now; AFC only reads it at spool assignment and Klipper start (TPU calibrated at 210C after Spoolman was set to 230C). The calibration moved to _LANE_CALIBRATE_PA_RUN, rendered after the refresh. - bdp_guard: an emergency stop during PA_CALIBRATE leaves the sensor in PA mode (FIRMWARE_RESTART does not reset it). When arming, read the mode register and switch the sensor back to probe mode with a fresh baseline before watching it. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
d49e65c0bb
commit
93ae8795b8
3 files changed
+54
-3
No files matched your search
@@ -40,6 +40,9 @@
|
||||
|
||||
import logging
|
||||
|
||||
REG_MODE = 48 # status_clk: 7 = PA mode, 2 = probe (endstop) mode
|
||||
REG_RESET_PROBE = 52 # set_normal: write 1 = take the current reading as zero
|
||||
MODE_PA = 7
|
||||
REG_EXT = 54 # extension marker 0xBD + version
|
||||
REG_DELTA = 64 # chk_delta, int16 little-endian
|
||||
EXT_MAGIC = 0xBD
|
||||
@@ -134,6 +137,31 @@ class BDPGuard:
|
||||
return False
|
||||
return len(data) == 2 and data[0] == EXT_MAGIC and data[1] >= 1
|
||||
|
||||
def _ensure_probe_mode(self, gcmd):
|
||||
# An emergency stop during PA_CALIBRATE leaves the sensor in PA mode
|
||||
# (FIRMWARE_RESTART does not reset it); bdpressure.py only switches
|
||||
# it back at the next homing move, after the guard is armed. In PA
|
||||
# mode the delta means nothing and could trip the guard. Register 48
|
||||
# is the mode: 7 = PA, 2 = probe.
|
||||
if getattr(self.sensor, 'last_state', 0):
|
||||
return # a calibration runs, leave the sensor alone
|
||||
try:
|
||||
mode = bytearray(self.i2c.i2c_read([REG_MODE], 1)['response'])
|
||||
if len(mode) != 1 or mode[0] != MODE_PA:
|
||||
return
|
||||
self.sensor.set_probe_mode()
|
||||
# new samples at the probe sample rate, then a fresh baseline
|
||||
self.reactor.pause(self.reactor.monotonic() + 0.5)
|
||||
self.i2c.i2c_write([REG_RESET_PROBE, 1])
|
||||
self.reactor.pause(self.reactor.monotonic() + 0.3)
|
||||
except Exception:
|
||||
logging.exception("bdp_guard: switching the sensor to probe mode failed")
|
||||
return
|
||||
msg = ("BDP_GUARD: bd_pressure was still in PA mode (stopped "
|
||||
"calibration?), switched to probe mode")
|
||||
logging.info(msg)
|
||||
gcmd.respond_info(msg)
|
||||
|
||||
def _stop_timer(self):
|
||||
if self.timer is not None:
|
||||
self.reactor.unregister_timer(self.timer)
|
||||
@@ -200,6 +228,7 @@ class BDPGuard:
|
||||
gcmd.respond_info("BDP_GUARD_ARM: bd_pressure load-check "
|
||||
"extension not found, guard not armed")
|
||||
return
|
||||
self._ensure_probe_mode(gcmd)
|
||||
self.phase_mode = mode
|
||||
self._reset_phase(phase)
|
||||
self.armed_until = self.reactor.monotonic() + self.timeout
|
||||
|
||||