# Bed check: scan the bed and warn about bumps, dips or too much height range
|
|||
|
|
# (needs extras/mesh_check.py, which explains the method and the limits)
|
||
|
|
#
|
||
|
|
# BED_SCAN_CHECK [BUMP=0.03] [RANGE=0.30]
|
||
|
|
# Scan now and report. Warns only, for use between prints. No heating and
|
||
|
|
# no contact: X and Y home if needed, Z homes with the Beacon's proximity
|
||
|
|
# mode. Replaces the active mesh, like any scan.
|
||
|
|
#
|
||
|
|
# BED_MESH_CHECK [BUMP=0.03] [RANGE=0.30] (extras/mesh_check.py)
|
||
|
|
# Only check the mesh that is loaded now.
|
||
|
|
#
|
||
|
|
# In PRINT_START a failed check pauses the print before the nozzle heats up:
|
||
|
|
# the toolhead goes up and out of the way so the plate can be cleaned.
|
||
|
|
# Resume levels, homes and scans again, and checks again
|
||
|
|
# BED_CHECK_IGNORE then Resume: the next failed check only warns
|
||
|
|
# Cancel works as usual.
|
||
|
|
#
|
||
|
|
# How the retry works: a PAUSE in a macro only stops the print file, the rest
|
||
|
|
# of the macro still runs, so everything after the check sits in
|
||
|
|
# _PRINT_START_FINISH and is only called when the check allows it. While a
|
||
|
|
# line of the file runs, virtual_sdcard.file_position is the start of that
|
||
|
|
# line. Resume sets the file back there (M26) and resumes, so the file runs
|
||
|
|
# PRINT_START again, as normal print file G-code: an error stops the print as
|
||
|
|
# it always does, which an error in a delayed_gcode would not (the file would
|
||
|
|
# carry on with the first layer).
|
||
|
|
#
|
||
|
|
# The pause goes through PAUSE, so through AFC_PAUSE: AFC_RESUME always restores
|
||
|
|
# AFC's saved position after a pause. Without saving it here, that could be a
|
||
|
|
# stale position from an earlier print, or X0 Y0 (seen after HEAT_SOAK).
|
||
|
|
# RESET_FAILURE first, because AFC does not save over a position it still holds.
|
||
|
|
# PAUSE sees _BED_CHECK_STATE.pending and only pauses: no retract, no park at
|
||
|
|
# the bucket, and RESUME skips _RESUME_PRINT and its purge (the filament is not
|
||
|
|
# loaded yet at this point).
|
||
|
|
|
||
|
|
[mesh_check]
|
||
|
|
bump_limit: 0.03
|
||
|
|
range_limit: 0.30
|
||
|
|
|
||
|
|
[gcode_macro _BED_CHECK_STATE]
|
||
|
|
description: Variables of the print start bed check
|
||
|
|
variable_pending: False # paused by the check, the next RESUME retries
|
||
|
|
variable_ignore: False # BED_CHECK_IGNORE: the next failed check only warns
|
||
|
|
variable_file_position: 0 # start of the PRINT_START line in the print file
|
||
|
|
variable_park_z: 100 # room to reach the plate; free of the bucket above Z10
|
||
|
|
gcode:
|
||
|
|
|
||
|
|
[gcode_macro _BED_CHECK_RESET]
|
||
|
|
description: Forget a pending bed check (start and end of a print)
|
||
|
|
gcode:
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=pending VALUE=False
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=ignore VALUE=False
|
||
|
|
|
||
|
|
[gcode_macro BED_SCAN_CHECK]
|
||
|
|
description: Scan the bed and warn about bumps, dips or too much height range (not during a print)
|
||
|
|
gcode:
|
||
|
|
{% set state = printer.print_stats.state %}
|
||
|
|
{% if state in ('printing', 'paused') %}
|
||
|
|
_ERROR MSG="BED_SCAN_CHECK: not during a print ({state})" DISPLAY="Bed scan: not during a print"
|
||
|
|
{% else %}
|
||
|
|
SAVE_GCODE_STATE NAME=_bed_scan_check
|
||
|
|
G90
|
||
|
|
{% if 'xy' not in printer.toolhead.homed_axes %}
|
||
|
|
_GUARD_ON PHASE=bed_check_home_xy
|
||
|
|
G28 X Y
|
||
|
|
_GUARD_OFF
|
||
|
|
{% endif %}
|
||
|
|
{% if 'z' not in printer.toolhead.homed_axes %}
|
||
|
|
_GUARD_ON PHASE=bed_check_home_z
|
||
|
|
G28 Z METHOD=PROXIMITY
|
||
|
|
_GUARD_OFF
|
||
|
|
{% endif %}
|
||
|
|
_GUARD_ON PHASE=bed_check_qgl
|
||
|
|
QUAD_GANTRY_LEVEL
|
||
|
|
_GUARD_ON PHASE=bed_check_z
|
||
|
|
G28 Z METHOD=PROXIMITY
|
||
|
|
_GUARD_ON PHASE=bed_check_mesh
|
||
|
|
BED_MESH_CALIBRATE RUNS=2
|
||
|
|
G1 Z10 F1200
|
||
|
|
_GUARD_OFF
|
||
|
|
RESTORE_GCODE_STATE NAME=_bed_scan_check
|
||
|
|
BED_MESH_CHECK {rawparams}
|
||
|
|
_BED_SCAN_CHECK_REPORT
|
||
|
|
{% endif %}
|
||
|
|
|
||
|
|
# Separate macro: rendered after BED_MESH_CHECK has run
|
||
|
|
[gcode_macro _BED_SCAN_CHECK_REPORT]
|
||
|
|
description: Helper for BED_SCAN_CHECK: warn when the check failed
|
||
|
|
gcode:
|
||
|
|
{% set check = printer.mesh_check %}
|
||
|
|
{% if check.result == 'fail' %}
|
||
|
|
_WARN MSG="Bed check: {check.summary}. A bump usually means something on the plate: clean it and scan again." DISPLAY="Bed check failed, see console"
|
||
|
|
{% elif check.result == 'none' %}
|
||
|
|
_WARN MSG="Bed check not done: {check.summary}" DISPLAY="Bed check not done"
|
||
|
|
{% else %}
|
||
|
|
M117 Bed check OK
|
||
|
|
{% endif %}
|
||
|
|
|
||
|
|
[gcode_macro BED_CHECK_IGNORE]
|
||
|
|
description: After the print start bed check paused the print: the next failed check only warns (press Resume after this)
|
||
|
|
gcode:
|
||
|
|
{% if printer["gcode_macro _BED_CHECK_STATE"].pending %}
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=ignore VALUE=True
|
||
|
|
RESPOND MSG="Bed check: press Resume. It scans once more and continues even if the check still fails."
|
||
|
|
{% else %}
|
||
|
|
RESPOND MSG="Bed check: the print is not paused by the check, nothing to ignore"
|
||
|
|
{% endif %}
|
||
|
|
|
||
|
|
# Called by _PRINT_START_GATE. FILE_POS: start of the PRINT_START line.
|
||
|
|
[gcode_macro _BED_CHECK_PAUSE]
|
||
|
|
description: Helper for PRINT_START: move away from the plate and pause, RESUME scans again
|
||
|
|
gcode:
|
||
|
|
{% set cfg = printer["gcode_macro _BED_CHECK_STATE"] %}
|
||
|
|
{% set summary = printer.mesh_check.summary %}
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=pending VALUE=True
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=file_position VALUE={params.FILE_POS|int}
|
||
|
|
G90
|
||
|
|
_GUARD_ON PHASE=bed_check_park
|
||
|
|
G1 Z{[cfg.park_z, printer.toolhead.axis_maximum.z - 5]|min} F1200
|
||
|
|
G1 X175 Y340 F6000
|
||
|
|
_GUARD_OFF
|
||
|
|
RESET_FAILURE
|
||
|
|
PAUSE
|
||
|
|
_STATUS STATE=paused
|
||
|
|
_WARN MSG="Bed check failed, print paused: {summary}. Clean the plate and press Resume to scan again. To print anyway: BED_CHECK_IGNORE, then Resume." DISPLAY="Bed check failed: clean plate, Resume"
|
||
|
|
|
||
|
|
# Called by RESUME instead of its normal chain while a check is pending.
|
||
|
|
# AFC_RESUME then restores the position that AFC_PAUSE saved in _BED_CHECK_PAUSE.
|
||
|
|
[gcode_macro _BED_CHECK_RETRY]
|
||
|
|
description: Helper for RESUME: go back to the PRINT_START line of the print file and resume
|
||
|
|
gcode:
|
||
|
|
{% set cfg = printer["gcode_macro _BED_CHECK_STATE"] %}
|
||
|
|
SET_GCODE_VARIABLE MACRO=_BED_CHECK_STATE VARIABLE=pending VALUE=False
|
||
|
|
# Clear the pause reason from the display
|
||
|
|
M117
|
||
|
|
RESPOND MSG="Bed check: levelling and scanning again"
|
||
|
|
M26 S{cfg.file_position|int}
|
||
|
|
RESUME_BASE
|