Commit Graph
3 Commits
Author SHA1 Message Date
mangavalkandClaude Opus 5.5 2b4750f8f4 2026 sim: drive the Unity simulation with the real remote over the radio
Dongle (app):
- bridge mode: stands in for the robot's radio (ch 96 / 250k / HXPD1,
  auto-ack, dynamic payloads, ack payloads). Received packets go to the PC
  as A5-framed 'R' frames; the PC's 'A' frames become the ack payload of
  the next packet, like robot/Comms.cpp; dropped after ~0.5 s without a
  refresh. 'S' status once a second.
- USART RX through circular DMA into a ring buffer, overrun stall
  disabled, error flags cleared: a burst (e.g. SignalRGB probing the port)
  used to deafen the app until a replug.
- RX test mode ('x') accepts protocol v4's dynamic-length packets.
- safeboot_flash.py --knock: keeps knocking across a replug to catch
  safeboot's cold-boot window when the app doesn't answer.

Unity:
- SimRemote sources: Keyboard, or the real remote via the dongle
  (DongleLink.cs: kernel32 serial, auto-finds the CH340, all port I/O on
  one background thread). Packets go into the firmware byte for byte, the
  robot's telemetry goes back on the ack, so the remote's display shows
  the sim. Tested end to end with the real remote.
- Dropped the USB joystick and robot-serial-harness inputs and the old
  Serial/Serial2/Serial3/HandleHoystick scripts (and their components in
  Main.unity): no USB links to remote or robot any more.
- Test panel: dongle status; no sideways scroll bar.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 22:48:41 +01:00
mangavalkandClaude Opus 5.5 91b5b99fd5 2026: OpenSCAD robot and remote, physical joint limits, model in Unity
hardware/openscad/ rebuilds the broken Fusion models as OpenSCAD:
body (top/bottom plate, standoffs, battery bay, switch), legs (coxa
bracket, femur link, tibia, horn adapters, TPU socks, servo cables),
the whole robot, and the remote (shell, lid, Nextion 3.5", JH-D400X-R4
sticks, 18650 UPS board, IMU, Teensy 4.0, USB-C breakout). Every part
was checked by slicing against the original STEP solids; the original's
bugs are fixed and listed in PLANNING.md.

The robot now uses a hexagon leg layout (corner legs 60 deg round from
the mid legs; the corner coxa brackets need turning on their splines).
Physical limits from a collision sweep of the model are in Config.h:
per-leg coxa limits and LEG_CLEARANCE_MM 56 (a leg is 55.2 mm wide at
the joints); the sim API exports them (version 7). sim_smoke passes.

Unity loads the model (export_unity.py -> Resources/OpenScadModel,
OpenScadModel.cs builds a new rig in place of the old scene's robot).
The PCB model's mounting holes now use the exact EasyEDA grid. README
shows renders of both.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-14 12:14:32 +01:00
mangavalkandClaude Opus 5.5 935526eab5 Firmware simulation, Unity project, and sim-verified robot fixes
Simulation
- sim/: the unchanged robot firmware compiled into hexapod_sim.dll
  against PC stand-ins (Arduino, Servo, Wire + register-level MPU6050,
  RF24 with matching-config radio), a kinematic body model (support
  plane + planted-foot odometry) that also drives the simulated IMU,
  and a headless smoke test (sim_smoke). build.ps1 builds and tests.
- Hexapod_Simulation_Unity/ folded in (history kept in a bundle
  outside the repo). Assets/HexapodSim loads the DLL, drives the
  existing leg rig, and offers joystick / keyboard / robot-serial
  input plus a test panel.

Robot (all found or confirmed in the simulation)
- Config.h geometry taken from the Unity model.
- IK femur elevation sign, gait stance direction, body pose
  rotation direction, yaw lever arm.
- Stance feet integrated from the current command; gait restarts at
  mid-stance; heading integrates the applied turn rate, only while
  walking.
- Leg clearance and reach checks (Limits::feetFeasible); walk command
  and body pose scaled as a whole, pose scale rate-limited, planted
  feet guarded so the body never snaps or legs collide.
- Robot-gyro self-leveling as an integrator.
- Heading mode: steering relative to the body; S walks backward.
- Standing height from the remote (STANCE_HEIGHT_RANGE_MM).

Protocol v3 (reflash both boards)
- CmdPacket gains body_height (22 bytes).

Remote
- Height slider (Nextion hHeight/nHeight, serial [ ]).
- Fixed unspecified I2C read order in RemoteIMU.

LEGACY/: owner's old Nextion HMI and remote hardware assets.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 00:37:12 +02:00